• Do not scratch the transducer with any tools.
Do not clean it with chemical or abrasive prod-
ucts.
Weekly cleaning:
External cleaning of the device:
• Clean the device outer surfaces with a soft
damp cloth using water and standard wash-
ing up liquid. Do not use abrasive products,
harsh detergents, alcohol, solvents or similar
products, which may cause permanent dam-
age to the device outer surface.
Cleaning of the water tank:
During normal use of the device, the salts
contained in the water could lead to the for-
mation of scale residues in the nebuliser unit
(transducer) (6) and the water tank (5). The
formation of scale residues could take place
more or less quickly, depending on the type
of water, its hardness and frequency of use of
the device. The higher the water hardness, the
faster the formation of deposits.
Scale residues decrease performance and can
hinder operation, so they need to be removed
at lease weekly.
At the end of the normal weekly cleaning
as described above, decalcify at least once a
week as follows:
• Repeat the operations indicated in the
"Daily cleaning" section.
• Pour a solution of equal parts of water
and white vinegar into the water tank
(5), enough to fill it. Leave the solution in
place for at least 4 hours (even better if
overnight).
• Rinse thoroughly and repeatedly with
drinking water and dry gently using a
soft cloth. If necessary, repeat the opera-
tion until all the scale residues have been
removed.
Warning!!
• Never place the device under running water.
• When the humidifier is not used for a long pe-
riod of time, dry the water tank (5) and trans-
ducer after cleaning.
• Do not scratch the transducer with any tools.
Do not clean it with chemical or abrasive
products.
TECHNICAL DATA
Mod. UM560 Humi
Dedicated AC/DC mains adaptor:
ELY mod. SAW-1201200
Rated specifications of AC/DC mains adaptor:
Input: 100-240 V
50/60Hz 0.5A
˜
Output: 12V
1200 mA
Humidifier:
Nominal power voltage: 12 V
Absorbed power: 15 W
Safety classification:
Mains adaptor + Device; Class II
Ultrasound transducer frequency: 2.45 MHz
Water tank capacity:
0.67 l approximately / 0.43 l usable
Nebulising capacity: about 38ml/h
Suitable for rooms with the following volume:
30m³
Autonomy: 6 hours approx
Noise level: below 40 dB
Type of device: continuous operation mode
Weight: 0.4 kg
Dimensions: 120x120x120 mm
Storage environmental conditions:
Ambient temperature: -40 / +70 °C
Relative humidity: 10 - 90 %
24
3
If
If
LE
ai
St
Th
20
Th
dic
mu
wa
dis
an
you
res
cia
the
sep
dis
tive
he
of
ma
ava
ag
ap
De
Th
Hu
me
EU