Dometic Travel Power
2.2
Operating the device safely
WARNING!
!
The output voltage of the Travel Power generator is considera-
bly higher than the output voltage of a regular vehicle generator.
No extra connections must be made to the Travel Power
generator under any circumstances.
The Travel Power generator with power box must never come
into contact with the regular 230-Vw network or the12/24-Vg-
system of the vehicle. If external power from the regular 230 V
network is wanted a two phase, three positioned selector or sim-
ilar must be installed between the Travel Power lines and the
regular lines ( Installation manual).
The power box cover is not to be removed at any time. Service
on the Travel Power must only be made by an authorised work-
shop.
Only appliances marked 220 V or 230 V may be connected to
Travel Power.
Extension cables for work outside the vehicle must be suitable
for outdoor use:
– 16 A: cable diameter 2.5 mm²; length maximum 100 m
– 25/36 A: cable diameter 4 mm²; length maximum 100 m
If the on/off switch is in the on-position when the vehicle engine
starts the Travel Power will immediately generate 230 V to the
outlet. Ensure that appliances not intended for use are switched
off or disconnected.
3
Target group
This operating manual is for the user of the generator.
EN
Target group
15