Installation advice
4
4
IMPORTANT
✓ The appliance should be installed, regulated and adapted to
function with other types of gas by a QUALIFIED INSTAL-
LATION TECHNICIAN.
Failure to comply with this condition will render the guaran-
tee invalid.
✓ The appliance must be installed in compliance with regula-
tions in force.
✓ Installation technicians must comply to current laws in force
concerning ventilation and the evacuation of exhaust gases.
✓ Always unplug the appliance before carrying out any main-
tenance operations or repairs.
TECHNICAL INFORMA-
TION FOR THE INSTALLER
In order to install the cooker top into
the kitchen fixture, a hole with the
dimensions shown in fig. 4.1 has to be
made, bearing in mind the following:
✓ within the fixture, between the
bottom side of the cooker top and
the upper surface of any other
appliance or internal shelf there
must be a clearance of at least 30
mm;
✓ the cooker top must be kept no less
than 200 mm away from any side
wall (fig. 4.1).
✓ the hob must be installed at least
60 mm from the wall.
✓ there must be a distance of at least
650 mm between the hob and any
wall cupboard or extractor hood
positioned immediately above (see
fig. 4.2).
✓ if the hob is installed over a built-in
oven, there must be a distance of at
least 30 mm between the two appli-
ances. The two appliances should
be connected to the gas supply with
independent connections.
All manuals and user guides at all-guides.com
INSTALLATION
✓ The appliance must be housed in heat-resistant units.
✓ These tops are designed to be embedded into kitchen
✓ The walls of the units must not be higher than work top
✓ Do not instal the appliance near inflammable materials
Fig. 4.1
fixtures measuring 600 mm in depth.
and must be capable of resisting temperatures of 105
°C above room temperature.
(eg. curtains).
Fig. 4.2
27