Dometic TEC 29EV Instrucciones De Montaje página 25

Ocultar thumbs Ver también para TEC 29EV:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 69
TEC29EV
TEC29EV control panel (fig. c, page 9)
Item
Description
1
Main switch
2
Motor connection
3
Remote control connection
4
Float connection (petrol tank)
5
12 V battery charger connection
6
Earth
7
230 V connection
8
Battery positive terminal
9
Cut-out switch
10.3
Connecting 230 V
A
NOTICE!
 Connect a relay or a switch to the vehicle's electrical system
so that the generator is not damaged when the external mains
is connected.
 Ensure that the electrical system is set up as follows:
– TN network:
The neutral conductor must be linked to the PE conductor
on the terminal via a jumper with a minimum diameter of
2.5 mm
sure that a safety switch (FI switch, 30 mA) and an in all-
pole overcurrent protection (e.g. circuit breaker, 13 A) are
installed.
– IT network:
Ensure that an insulation monitor and an in all-pole over-
current protection (e.g. circuit breaker, 13 A) are installed.
 Connect the generator so that it takes priority over the power
supply.
EN
All manuals and user guides at all-guides.com
Connecting the electrical power to the generator
2
. To protect against automatic shutdown, make
25

Publicidad

Tabla de contenido
loading

Tabla de contenido