Servicing the generator
Interval
In the first month
or after 20 hours.
Every 3 months or
after 50 hours.
Every 6 months or
after 100 hours.
Once a year or
every 300 hours
Every two years
11.2

Preparing maintenance work

!
CAUTION!
Note the following for all maintenance work:
 The generator must not be running.
 All the parts must be cooled down.
➤ Switch the generator to no function with the main switch (fig. 4 1,
page 4).
➤ Disconnect the positive terminal of the supply battery.
➤ Open the generator cover.
For maintenance work, you can take the generator out (fig. j, page 16):
!
WARNING!
The mounting plate with generator is very heavy (> 40 kg) and
could fall out the housing if you take it out too far.
➤ Undo the fastening screws (1).
➤ Remove the mounting plate (2) with the generator a bit from the
housing (3).
40
Inspection/maintenance
➤ Change the oil.
➤ Check the air filter (chapter "Servicing the air filter" on
page 42).
➤ Check the air filter (chapter "Servicing the air filter" on
page 42).
➤ Change the oil.
➤ Check the spark plug (chapter "Servicing the spark plugs"
on page 43).
➤ Check the valves.
➤ Check the vibration damper.
➤ ePower T only: Check the fuel tank and fuel filter.
➤ ePower T only: Check the petrol supply lines.
➤ ePower T LPG only: Check the gas supply lines.
ePower T, ePower T LPG