Real Time
Access to this menu requires following the procedure according to the type of connection to be made
NOTE: in case of a USB connection, the installation of the drivers could be required in order to recognize the
peripheral. If the drivers are not automatically recognized, the following path must be indicated to the system:
C:\Programmi\Xwin\Driver\ and the file fs-vcom.inf must be selected
Once connection has been made, a number of FOGGY parameters will be displayed. Besides these, the information
will be displayed in real time relating to the state of the System, of the Inputs, of the boiler, of the liquid and any faults
in existence.
E
N
G
Choice of Device: displays the device model, Foggy30 or Foggy50, and the
installed firmware version.
SYSTEM: displays the state of system operation and whether ready to smoke.
System ON: System Switched on from Remote Control or SMS (red
light)
System STATE: System Switched on from ARM input (red light)
Ready: System ready to smoke (green light)
Boiler heating: shows whether boiler heating is Continuous (red
light), Pulsed (green light), Off (grey light) or disengaged due to
overheating(yellow light)
State of supply: shows whether the system is in SUPPLY IN PROGRESS (red
light), SUPPLY MAINTENANCE (yellow light) or no supply (grey light).
Temperature: shows the boiler temperature in real time. In case the temperature is too
high, "err" is indicated.
Operator name: shows SIM phone operator name.
SIM Credit: shows the phone credit in SIM.
Level: shows the level of the liquid in the tank and the number of supply operations still
possible.
Liquid expiry: shows the expiry date of liquid in tank set by AVS Electronics.
Operating Mode: displays the set operating mode.
LED state: remotization of the 3 LEDs on board FOGGY.
INPUTS: shows the state of the FOGGY inputs. An activated input is
displayed with green light. The light is grey if the input is deactivated.
T: Tamper ; A: ARM ; P: Primary ; S: Secondary ; D: Disable ; F: Fire
Faults found: shows the faults that could affect FOGGY in real time.
- 48 -