InSinkErator C1300 Instalacion, Cuidado & Uso página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5
FINAL WATER CONNECTION
A
Brass Nut
Property Damage: Join remaining tube
to cold water supply only.
6
FILL TANK & THEN CONNECT POWER
A
Scalding Hazard: The faucet dispenses water up
to 210ºF, which can instantly cause scalds or burns.
Use care when operating this appliance.
B
Property Damage: A standard grounded outlet within
30" of the dispenser is required under the sink. Do
not use an extension cord set with the dispenser.
All manuals and user guides at all-guides.com
Ferrule
Personal Injury: This tank is a non-pressurized tank. DO NOT modify this system.
DO NOT close vent tube or connect other type dispensers or valves to the tank. Use
only the In-Sink-Erator dispenser faucet supplied. Use only parts provided. Contact
an authorized In-Sink-Erator Service agent for repairs or replacement components.
Fire Hazard: To minimize possibility of fire, DO NOT store flammable items such as
rags, paper or aerosol cans near the tank. DO NOT store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
Property Damage: To avoid water damage, replace any loose or split tubing.
Periodically inspect the unit for any signs of leakage and immediately remove from
service any unit suspected of leaking.
■ ■
Install a compression fitting, T-fitting
or saddle valve onto the cold water
supply line.
■ ■
At the end of the copper 1/4" tube,
slide the fitting's brass nut and ferrule
over the tube.
■ ■
Insert the copper tube into the 1/4"
compression fitting and tighten.
■ ■
Turn on the cold water supply.
■ ■
Depress or twist the dispenser handle
and hold it until water flows from the spout.
■ ■
Run the water for at least 2 minutes to
flush lines (both the hot and cold handles
independently if applicable).
■ ■
Check all connections to ensure they are
tight and that there are no leaks.
■ ■
Plug in instant hot water tank.
Water will be cold at first.
Allow 12-15 minutes for water to reach
target temperature.
Gurgling or hissing is normal during the
initial heating cycle.
For Technical Assistance
1-800-845-8345