HIDDY
INSTALLATION HIDDY 350A
PRE-INSTALLATION CHECKS
The leaf must be fixed firmily on the hinges to the pillars, must not be
flexible during the movement and must move without frictions.
Before the installation of HIDDY 350A, verify all dimensions etc.
There's no need for any modification, if the gate is like that shown
in Fig. 1.
Gate features must be uniformed with the standards and laws in
force. The gate can be automated only if it is in a good condition and
its conditions comply with the EN 12604 norm.
- The gate leaf does not have to have a pedestrian opening. In the
opposite case it is necessary to take the appropriate steps, in
accordance with EN 12453 norm (for instance; by preventing the
operation of the motor when the pedestrian opening is opened, by
installing a safety microswitch connected with the control panel).
- No mechanical stop shall be on top of the gate, since mechanical
stops are not safe enough.
PREPARE THE CEMENTATION OF THE BOX
- Excavate a trench next to the pillar (Fig. 3).
- On the bottom of foundation box a 50 mm Ø pipe should be fitted to
drain water. On one side of the box another pipe 32 mm Ø should
be fitted. Pipe should be flexible, sturdy and insulated type, to let out
electrical wiring (use holes on internal side of gate opening).
ENSURE THAT THE CABLE JOINTS ARE MADE inside a sealed
junction box OUTSIDE THE HIDDY 350A BOX (The junction box can
be built-in to the wall or surface mounted, positioned at a safe height
and must comply with the relevant standards).
- Use a level to position the box so that the upper edge of the cover
corresponds with the finished floor level.
- The centreline of the pintles must be perfectly in line with the centreline
of the operating arm mounting shaft.
- Cement in, taking care to ensure that cement does not fall into
the box and checking that the short sides of the box are perfectly
parallel to the gate when in the "CLOSED" position.
- Insert the bolts for cover fixing in places cut into the foundation box.
INSTALLING THE HIDDY 350A
- Make sure that the pivot of foundation box is well greased. Lay down
the ball (A) end insert drive rod (B) after fitting release system (picture
7).
- Fit gate bracket plate (C) through its pivot in the drive rod (picture 8).
- Place gate leaf between upper hinge and plate of gate bracket (hinge
and pivot of gate bracket plate should be perfectly aligned).
- Weld carefully bracket plate on the leaf.
- Fit adjusting open position bolt D (picture 11) M10X30 and relevant
nut.
- Fit HIDDY 350A operator inside the foundation box (picture 4).
- Screw on pulling lever adjusting bolt (E) M10X50 and relevant nut
(picture 11).
- Fit joint lever (F) (picture 4).
- ATTENTION: joint lever (F) must
be fitted as shown in picture
4. Should it be difficoult to fit,
operate electrically the reducer.
8
All manuals and user guides at all-guides.com
(F)
Parts to install meeting the EN 12453 standard
COMMAND TYPE
Skilled persons
(out of public area*)
with manned operation
A
with visible impulses
C or E
(e.g. sensor)
with not visible impulses
C or E
(e.g. remote controldevice)
automatic
C and D, or E
* a typical example are those shutters which do not have access to any public way
A: Command button with manned operation (that is, operating as long as activated)
B: Key selector with manned operation, like code EDS1
C: Adjustable power of the motor
D: Safety strips and/or other safety devices to keep thrust force within the limits of
EN12453 regulation - Appendix A.
E: Photocells, like code EFA1 (To apply every 60÷70cm for all the height of the
column of the gate up to a maximum of 2,5m - EN 12445 point 7.3.2.1)
C
B
A
USE OF THE SHUTTER
Skilled persons
Unrestricted use
(public area)
B
non possibile
C or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
C and D, or E
3