ADJUSTMENT OF HIDDY 350A MECHANICAL STOPPER
The HIDDY 350A system requires no floor stops or other accessories
as the gate travel limit is determined by means of set screws located
internally of the box.
Access to the screws is gained by lifting the cover.
- To adjust the travel limit for the opening movement of the gate, simply
turn the screw (D) left or right as appropriate, then secure the lock
nut to prevent the screw from slipping out of position subsequently
(Fig. 11).
Same adjusting must be done also on bolt (E) for closing, in order to let the
mechanism block again when unblocked.
IMPORTANT: Please make sure that the leaves stop
against the mechanical stoppers inside
the operator before they reached the
ground mechanical stopper. In not
adjusted, unblocking will be impossible.
EMERGENCY RELEASE
To be carried out after having disconnected the power supply to
the motor.
In order to carry out the manual operation of the gate leaf the followings
must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for
the operator;
- That the physical effort necessary to move the gate leaf should not be
higher than 225 N, for doors/gates for private dwellings, and, 390 N
for doors/gates for commercial and industrial sites ( values indicated
in 5.3.5 of the EN 12453 norm) .
In the case of a power cut, the gate can be opened manually by
releasing the lock on the operating lever to allow the gate to move
freely (Fig. 8).
IMPORTANT: Please make sure that the leaves stop
against the mechanical stoppers inside
the operator before they reached the
ground mechanical stopper. In not
adjusted, unblocking will be impossible.
SAFETY CLUTCH ADJUSTMENT
There is no mechanical safety clutch with the HIDDY 350A.
Therefore it is necessary to operate this operator with an electronic
control panel fitted with an electronic force regulator.
Use the ECA8 (for one or two single-phase motors) electronic control
unit.
ELECTRICAL SAFETY DEVICES
The installation must be installed according to the current regulations
and laws. Use the ECA8 (for one or two single-phase motors) electronic
control unit. For connections and technical data of accessories refer to
the appropriate booklets.
MAINTENANCE
To be undertaken by specialized staff after disconnecting power
supply.
Make certain that moving parts located inside the box are greased once
a year, and check the force transmitted through the drive to the gate.
In the event that the need for servicing or repairs should arise, the
speed reducer can be removed from the box without taking down the
gate.
- Lift the cover from the box, isolate the motor from the power supply by
disconnecting the cable, then remove the curved lever: the gate can
now swing freely.
- Then unscrew the for nuts that fix the motor.
10
All manuals and user guides at all-guides.com
E
ACCESSORIES
For the connections and the technical data of the optional
equipments follow the relevant handbooks.
FOUNDATION BOX FOR HIDDY 350A
RELEASE WITH HANDLE
Yellow-Green:
Blue: Common
Brown: Open
Black: Close
DX
D
F
cod. EIC5
code EIS5.L
Yellow-Green:
Blue: Common
Brown: Close
Black: Open