  • Página 1 AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender Installation Guide PN 613-10857-00 Rev A...
  • Página 2 The information provided herein is subject to change without notice. In no event shall Allied Telesyn International, Corp. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn International, Corp.
  • Página 3: Electrical Safety And Emission Statement

    Electrical Safety and Emission Statement Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Página 5: Tabla De Contenido

    Fiber Optic Port 1 (P1) ................4 Fiber Optic Port 2 (P2) ................4 AC Power Socket ..................4 Port and System LEDs ................5 Installing the AT-EX1001SC/GM1 Multimode Extender........ 6 Planning the Installation ................6 Selecting a Site ................... 7 Verifying Package Contents ..............7 Reviewing Safety Guidelines ..............
  • Página 7: Welcome To Allied Telesyn

    All web-based documents relating to this product and other Allied Telesyn products can be downloaded from the web site in PDF format. Document Conventions This guide uses several conventions that you should become familiar with first before you begin to install the product.
  • Página 8: Contacting Allied Telesyn

    Contacting Allied Telesyn There are several ways that you can contact Allied Telesyn technical support: online, telephone, fax, or e-mail. Online Support You can request technical support online by filling out the Online Technical Support Form at www.alliedtelesyn.com/forms/support.htm. Telephone and Fax Support...
  • Página 9: Returning Products

    Fax: international code + 425-489-9191 FTP Server If you need a device driver for an Allied Telesyn device and you know the name of the driver, you can download the software by connecting directly to our FTP server at ftp://gateway.centre.com.
  • Página 10: For Sales Or Corporate Information

    Tell Us What You Think If you have any comments or suggestions on how we might improve this or other Allied Telesyn documents, please fill out the “AT-EX1001SC/GM1 Installation Guide Feedback” on page 27 and return the form to us at the address or fax number provided.
  • Página 11: Overview

    Overview The AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender (Figure 1) allows you to extend the maximum distance of standard multimode fiber cable for 1000Base-SX Gigabit Ethernet beyond the distance limitations imposed by the current IEEE 802.3z standard. With this unit, you can extend your network up to 2 kilometers (1.24 miles) over 50/125 or 62.5/125 micron multimode fiber...
  • Página 12: Gigabit Ethernet Technology And Fddi Technology

    Figure 2 illustrates a network that incorporates two AT-EX1001SC/GM1 Gigabit Multimode Extenders. The units interconnect an AT-8224XL Fast Ethernet Switch with an AT-A15/SX Expansion Module and an AT-9006...
  • Página 13: Features And Components

    AT-A15 Expansion Module Figure 2 Example Topology Features and Components The AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender has the following features: One 1000Base-X fiber optic port (Port 1) with a maximum operating distance of 2 kilometers (1.24 miles) using 50/125 or 62.5/125 micron...
  • Página 14: Fiber Optic Port 1 (P1)

    2 kilometers (1.24 miles). This port operates in full-duplex mode at 1000 Mbps. Note Port 1 must be connected to Port 1 on another AT-EX1001SC/GM1 Multimode Extender. Do not connect Port 1 to any other type of network device.
  • Página 15: Port And System Leds

    AT-EX1001SC/GM1 Installation Guide Port and System LEDs The front panel has several LEDs that display the status of the ports and the unit. Table 1 describes the functions of the LEDs. Table 1 AT-EX1001SC/GM1 LED Indicators Description State Indicates System LEDs...
  • Página 16: Installing The At-Ex1001Sc/Gm1 Multimode Extender

    275 m (754 ft) multimode fiber 220 m (604 ft) 1. Assumes that the opposite end of the fiber cable is connected to P1 on another AT-EX1001SC/GM1 Gigabit Ethernet Mulitmode Extender. Note Do not use single-mode fiber on either port of the AT-EX1001SC/GM1...
  • Página 17: Selecting A Site

    Verifying Package Contents Make sure that the following items are included in your package, If any of the following items are missing or damaged, contact your Allied Telesyn sales representative. One AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender...
  • Página 18 Warning Lightning Danger: Do not work on this equipment or cables during periods of lightening activity. ! 9 Warning Power cord is used as a disconnection device: To de-energize equipment, disconnect the power cord. ! 10 Warning Electrical-Type Class 1 Equipment: This equipment must be earthed.
  • Página 19: Installing The Unit

    Dust contamination can adversely impact the operation of the ports. Remove the dust cover from Port 1 (P1) on the AT-EX1001SC/GM1 Multimode Extender. Connect the appropriate fiber optic cable to Port 1 (P1) on the Gigabit Ethernet multimode extender.
  • Página 20: Troubleshooting

    If after connecting one of the units to the host device the PLL Lock and SC LEDs of Port 2 fail to light up, do the following: Make sure that both the host device and the AT-EX1001SC/GM1 Multimode Extender are powered up and functioning properly.
  • Página 21: Technical Specifications

    Power Consumption 12 watts Warranty Registration The AT-EX1001SC/GM1 Gigabit Ethernet Multimode Extender comes with a Limited Lifetime Warranty. The power supply has a five (5) year warranty. When you have finished installing the unit, you should register your product by completing the enclosed warranty card and sending it in, or by visiting our web site at www.alliedtelesyn.com/forms/warranty.htm and completing...
  • Página 23: Appendix A

    Appendix A Translated Safety and Emission Information Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Vigtigt: Dette tillæg indeholder oversættelser i flere sprog af sikkerhedsadvarslerne i denne håndbog.
  • Página 24 Standards: This product meets the following standards. U.S. Federal Communications Commission RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Página 25 AT-EX1001SC/GM1 Installation Guide ! 12 PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and shall be easily accessible. ! 13 CAUTION: Air vents must not be blocked and must have free access to the room ambient air for cooling.
  • Página 26 Standarder: Dette produkt tilfredsstiller de følgende standarder. Radiofrekvens forstyrrelsesemission EN55022 Klasse A ADVARSEL: I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse. Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger. Immunitet EN50082-1 Elektrisk sikkerhed EN60950, UL 1950 Laser EN60825 SIKKERHED...
  • Página 27 AT-EX1001SC/GM1 Installation Guide Eisen: Dit product voldoet aan de volgende eisen. RFI Emissie EN55022 Klasse A WAARSCHUWING: Binnenshuis kan dit product radiostoring veroorzaken, in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen. Immuniteit EN50082-1 Electrische Veiligheid...
  • Página 28: Température De Fonctionnement

    Normes: ce produit est conforme aux normes de suivantes: Emission d’interférences radioélectriques EN55022 Classe A MISE EN GARDE : dans un environnement domestique, ce produit peut provoquer des interférences radioélectriques. Auquel cas, l’utilisateur devra prendre les mesures adéquates. Immunité EN50082 - 1 Sécurité...
  • Página 29 AT-EX1001SC/GM1 Installation Guide Standardit: Tämä tuote on seuraavien standardien mukainen. Radioaaltojen häirintä EN55022 Luokka A VAROITUS: Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä, missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin. Kestävyys EN50082-1 Sähköturvallisuus EN60950, UL 1950 Laser EN60825 TURVALLISUUS VAROITUS Luokan 1 Lasertuote.
  • Página 30 Standard: Questo prodotto è conforme ai seguenti standard. Emissione RFI (interferenza di radiofrequenza) EN55022 Classe A AVVERTENZA: in ambiente domestico questo prodotto potrebbe causare radio interferenza. In questo caso potrebbe richiedersi all’utente di prendere gli adeguati provvedimenti. Immunità EN50082-1 Sicurezza elettrica EN60950, UL 1950 Laser EN60825...
  • Página 31 AT-EX1001SC/GM1 Installation Guide Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. RFI stråling EN55022 Klasse A ADVARSEL: Hvis dette produktet benyttes til privat bruk, kan produktet forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler. Immunitet EN50082-1 Elektrisk sikkerhet EN60950, UL 1950...
  • Página 32 Padrões: Este produto atende aos seguintes padrões. Emissão de interferência de radiofrequência EN55022 Classe A AVISO: Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas. Imunidade EN50082-1 Segurança Eléctrica EN60950, UL 1950...
  • Página 33 AT-EX1001SC/GM1 Installation Guide Estándares: Este producto cumple con los siguientes estándares. Emisión RFI EN55022 Clase A ADVERTENCIA: en un entorno doméstico, este producto puede causar radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
  • Página 34 Standarder: Denna produkt uppfyller följande standarder. Radiostörning EN55022 Klass A VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket kan tvinga användaren till att vidtaga erforderliga åtgärder. Immunitet EN50082-1 Elsäkerhet EN60950, UL 1950 Laser EN60825 SÄKERHET VARNING! Laserprodukt av klass 1. VARNING! Laserstrålning när enheten är öppen.
  • Página 35: Appendix B

    ______________________________________________________________________ Detailed description (Please use separate sheet). Please also fax printouts of relevant files such as batch files and configuration files. When completed, fax this sheet to the appropriate Allied Telesyn office. Fax numbers can be found on page viii.
  • Página 37: Appendix C

    Allied Telesyn. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of this guide.

Tabla de contenido