Measurements; Oscilloscope; Performing Oscilloscope Measurements - Hella Gutmann mega macs 56 Guía De Instalación Rápida

Ocultar thumbs Ver también para mega macs 56:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 93
mega macs 56

8 Measurements

EN
Here you can select measured variables and channel. Then you can perform various measurements.
Measurement technology involves digital signal acquisition and output. A voltage signal is scanned and stored at
intervals of a few microseconds. Once there are enough values stored, the scans are displayed as a signal curve on-
screen.
8.1

Oscilloscope

The use of the measurements menu requires the optionally available measurement module (MT 56).
The oscilloscope can be used for measuring and/or depicting the following measured variables:
Voltage
Current
Resistance
Current measurements are allowed exclusively using the clamp meter from Hella Gutmann. Depending on the
required measurement, different meters are to be used.

8.1.1 Performing Oscilloscope Measurements

Proceed as follows to perform oscilloscope measurements:
1. Insert the test lead into the MT 56 and connect it to the relevant component.
2. Select >Measurements< in the main menu.
3. Activate the check box for the desired measured variable and the oscilloscope channel.
4. Confirm the selection with
Measurement will be started.
5. Use
The ideal measuring range of the device can alternatively be determined automatically with
6. Start Auto Set with
46
NOTE
The use of the measurements menu requires the optionally available measurement module (MT
56).
CAUTION
Overvoltage
Fire hazard/danger of destruction of the device and its surroundings
Comply with the max. permitted voltage load of the oscilloscope channels:
Alternating voltage (AC): max. 160 V
Direct current voltage (DC): max. 200 V
.
to set the time and measured variable ranges.
>
.
Measurements