Adjustment of the flow rate limiting device. (ref. picture 2)
- remove the flow control knob (6), pulling out the plate (7) and unscrewing the screw (8).
- remove the flow limit device (9), rotate it clockwise and insert it in one of the 7 stop positions that stop
the rotation of the knob.
- temporarily mount the knob and check that the flow has been reduced as required.
- complete the fitting of the knob by tightening the screw (8) and fitting the plate (7).
MAINTENANCE
REMOVING THE NON-RETURN VALVE (10) AND FILTER (11) (ref. picture 3)
- Turn off the hot and cold inlets.
- Empty the mixer of water by opening the flow knob (6).
- Unscrew the non-return valve (10) using a wide-bladed screw driver.
- Remove the filter (11).
- Clean the filter with a brush and rinse it. If the filter is furred up, use our product MASTER LIBBY
Art. ZA00800. To reassemble the valve and filter, proceed in the reverse order.
CLEANING OR REPLACEMENT OF THE THERMOSTATIC CARTRIDGE (ref. picture 4)
- Close the cold and hot water inlets.
- Empty the mixer of water by opening the flow rate handle (6) (picture 1).
- Remove the handle (5) unscrewing the small cap (7) and the screw (8).
- Remove the adapter (12).
- Remove the lock nut (13).
- Unscrew the caps (14) with the 30 mm wrench and remove the mixing valve (15).
- Cleaning of the thermostatic valve: clean the encrusted parts with a brush and rinse ; in case of
calcareous incrustations; dip the thermostatic valve in the product Cisal Master Libby (article ZA00800)
and then rinse.
- Replacement of the thermostatic mixing valve
- Screw the caps (14) by DYNAMOMETRIC WRENCH applying a screwing torque of 10Nm.
- Insert the lock nut (13) with the notch (=) turned upward and aligned with the reference placed on the
thermostatic mixer (ref. picture 4/A).
- Assemble the adapter (12) again.
- Open the cold and hot water inlets.
CALIBRATION
- Take the temperature of the mixed water.
- Bring the temperature of the mixed water to a value between 38°C and 40°C; by rotating the rod of the
thermostatic valve.
- Insert the handle (5) with the indication of the 38°C aligned with the reference placed on thermostatic
mixer (REF.pict. 4/B).
- Tighten the screw (8) and assemble the small cap (7) again.
REPLACEMENT OF THE CERAMIC HEADVALVE (ref. picture 5)
- Close the cold and hot water inlets.
- Empty the mixer of the water; by opening the handle of the flow rate (6)
- Disassemble the handle (6); removing the small cap (7) and unscrewing the screw (8)
- Remove the adapter (12)
- remove the lock nut (16)
- Disassemble the ceramic headvalve (17) by unscrewing it with a 17 mm wrench.
- Mount the new ceramic headvalve; by screwing it down with a 17 mm wrench
- assemble the lock nut again (16) (see the paragraph 'Adjustment of the flow rate limiting device' ).
- Assemble the adapter (12) again.
- Rotate the rod of the ceramic headvalve clockwise up to its lock.
- Insert the handle (6) with the button turned forwards.
- Tighten the screw (8) and assemble the small cap again (7).
If over time there is a reduction of the maximum flow-rate, clean or replace the filters and
the aerator fitted on the spout. See the " Master Libby" leaflet enclosed in the packaging for
details of the maintenance of the finishings.