6. You hear a whistle
1. Input filters clogged.
a. Proceed as in section 1 of clogged input filters.
2. Non-return valves may be blocked.
a. Follow the instructions for cleaning the filters specified in section 1 by checking with a
small screwdriver if, when applying force, the valve is introduced into the thermostat
and automatically recovers its closing position as soon as we stop using force.
b. If they become blocked, replace check valves.
3. There may be impurities or traces of lime in the thermostatic cartridge.
a. Follow disassembly and cleaning guidelines.
7. The temperature does not change even if the knob is turned
• Thermostatic cartridge could be blocked.
- Without disassembling it, turn the knob repeatedly pressing the button taking it from
one end to the other.
- If the problem persists, replace the cartridge using the tool provided.