General Safety Instructions; Intended Usage - Siemens 1FT6 02 Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 61
1

General Safety Instructions

The servomotors correspond to the harmonized standards of the
EN 60034 (VDE 0530) series EN 60034-1, EN 60034-6, EN 60034-9 and EN 60204-1.
The three-phase servomotors 1FT6 conform to the following:
73/23/EEC
Standard motors conform to UL regulations. The rating plates of these motors are marked
with UR.
Ensure that your end product conforms to all currently valid legal requirements.
Follow the compulsory national, local and installation-specific regulations.
Three-phase servomotors are exclusively intended for fitting in another machine or
machines.
These motors must not be brought into use until it has been established that the end
product conforms to the currently valid directives.
The operating manual is valid in conjunction with the SIEMENS project planning guide
"Three-phase motors for feed and main spindle drives" for the motors concerned.
All safety instructions must be observed during the transport, storage, assembly,
disassembly and operation of the servomotors!
Failure to observe the instructions can lead to serious personal injuries or property damage.
The motors' rotors contain permanent magnets with high magnetic flux densities which exert
strong attractive forces on ferromagnetic bodies.
People fitted with a heart pacemaker are at risk in the vicinity of a disassembled rotor. Data
stored on electronic and magnetic data media may be destroyed.
It is forbidden to use these servomotors in areas at risk of explosion, unless this is expressly
authorized.
Thermal hazards
The surface temperatures of the motors may exceed 140 °C (284 °F).
Do not touch hot surfaces!
Temperature-sensitive components (electric lines, electronic components) must not touch
hot surfaces.
Overheating in the motors may destroy the windings and bearings, and demagnetize the
permanent magnets.
Only operate the motors with effective temperature control.

Intended Usage

Usage for the intended purpose includes observing all the specifications in the operating
manual and the project planning guide for servomotors.
Siemens AG
ENGLISH
Low Voltage Directive.
610.43 410.21
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1ft6 10 serie

Tabla de contenido