THE LIGHT ABOVE SHOWS THAT THE INDICATED
FILTER IS OVERFILLED. IN THAT CASE, FOR THE
SYSTEM TO WORK CORRECTLY, PLEASE CONTACT
YOUR DISTRIBUTOR TO REPLACE THEM.
GRSV
F7
(*) The electronic board includes an LED system to indicate the condition of the filters. If they
are off, the filters are in correct condition. When they turn red, the filter of the LED that is
switched on must be replaced.
(**) Details of the plug and play cables (see Installation Manual - QR code link).
IMPORTANT:
- If the customer has NOT purchased the sensor, do NOT touch ANY part of the terminal
strip supplied, i.e. cables 18 and 20 must be together (bridge mode).
- If the customer HAS purchased the sensor, separate the grey cables 18 and 20 from the
terminal strip for the equipment to work correctly. This will ensure the sensor controls the
equipment in line with the air quality.
· Side black cable = 230V electrical power supply
· Lower grey cable = for connection to Z3D air quality sensor to indicate filter inspection,
2 cables marked 5 and 6 that correspond to the numbers where they should be connected
inside the sensor.
· Side grey cable = for connection to Z3D air quality sensor for ON/OFF control of the
purifier according to the indoor air quality limits. These are 2 cables marked 18 and 20
that correspond to the numbers where they should be connected inside the sensor.
LOCATION
HORIZONTAL
suspended
TRANSVERSAL
10
AIR PRO 2000-3000
G4
H14
REPLACEMENT
on mount
üüüüü
FILTER
VERTICAL