V2 CU1 Manual Del Usuario página 14

Ocultar thumbs Ver también para CU1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
Programming of the level of intervention of
the sun sensor
To set the level of intervention of the sun sensor it is necessary to
use a remote control previously stored and proceed as follows:
WARNING: to make the awning open the sun sensor has to
detect a value higher then the set threshold value for at least 8
minutes. To make it close, the sensor has to detect a value lower
then the set threshold value for at least 8 minutes.
Interruptions of light (due to clouds) shorter than a minute are
not detected, while the 8-minute timer is set at zero when longer
than one minute.
1. Activate ADLER programming by holding down buttons 4 and
6 until the 6 LEDs turn on
2. Release the buttons and enter the code 12 11 18
The two highlighted digits indicate the remote control channel
recorded in the control unit; for channel 1 the digits are 11,
for channel 2 the digits are 12, for channel 3 the digits are 13,
etc up to channel 6. Once the codes have been entered, the
LED of the selected channel will blink for 2 minutes after
which it exits programming.
3. Press and keep pressed (for 5 about seconds) the button PROG
of the transmitter until the motor moves jerkily in both the
ways showing that it enters the storing.
4. The number of jerks made by the motor corresponds to the
level currently set:
1 jerk
= level 1 = 2 Klux
2 jerks = level 2 = 5 Klux
3 jerks = level 3 = 10 Klux (default)
4 jerks = level 4 = 20 Klux
5 jerks = level 5 = 40 Klux
5. Release the key PROG
6. To increase the level press button UP, to decrease it press
button DOWN.
7. As soon as the control unit receives the control, it shows the
new level moving the motor with the corresponding number
of jerks.
8. To exit the programming press STOP: the motor displays again
the set level and exits.
9. To exit the programming mode, wait for the led to switch off
or press key 1 to exit immediately.
All manuals and user guides at all-guides.com
Programming of the level of temperature
The temperature can be set on 5 levels, under which the sun
sensor must not open the awning, even if the light intensity has
exceeded the level set.
This function is particularly useful in Countries with wintry
weather, where sunny but very cold days are frequent. In this
case, it is not necessary to open the awnings, to let the sun warm
the inner rooms.
To set the level of temperature it is necessary to use a remote
control previously stored and proceed as follows:
1. Activate ADLER programming by holding down buttons 4 and
2. Release the buttons and enter the code 12 11 21
3. Press and keep pressed (for 5 about seconds) the button PROG
4. The number of jerks made by the motor corresponds to the
5. Release the key PROG
6. To increase the level press button UP, to decrease it press
7. As soon as the control unit receives the control, it shows the
8. To exit the programming press STOP: the motor displays again
9. To exit the programming mode, wait for the led to switch off
12
6 until the 6 LEDs turn on
The two highlighted digits indicate the remote control channel
recorded in the control unit; for channel 1 the digits are 11,
for channel 2 the digits are 12, for channel 3 the digits are 13,
etc up to channel 6. Once the codes have been entered, the
LED of the selected channel will blink for 2 minutes after
which it exits programming.
of the transmitter until the motor moves jerkily in both the
ways showing that it enters the storing.
level currently set:
1 jerk
= level 1 = sensor disabled (default)
2 jerks
= level 2 = 0°C
3 jerks
= level 3 = 5°C
4 jerks
= level 4 = 10°C
5 jerks
= level 5 = 15°C
button DOWN.
new level moving the motor with the corresponding number
of jerks.
the set level and exits.