Report Generation Unit of the SPG series to the machine. A
model version with a support bracket and connection ports
for the data logger is available upon request.
5
Indication of Errors Related to the Heating Element
Error indications that may appear on the 7-segment display
are composed of the letter E and a code number. When an
error is cleared while the system is still running and provid-
ed the cleared error was the only one that occurred, the sys-
tem changes back to control mode. No re-start is needed. As
soon as an error condition is detected, the heating element
is switched off. The control unit supports the following er-
ror messages:
Error E01
Temperature sensor not connected or ohm value too
high
Error E02
Heating
element
mum (> 280 °C)
Error E03
Short-circuit at the temperature sensor input
6
Service and Repair
As the product is used in applications sensitive to safety
considerations, it may be serviced and repaired only on our
premises or by partners who were specifically trained and
authorized by us. Thus, constantly high standards of opera-
tion quality and safety are maintained.
Non-compliance with this provision will dispense the
manufacturer from any warranty and liability claims for
the product and any consequential damage.
Important
7
Service and Repair Contact
HÜRNER Schweisstechnik
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Web: www.huerner.de
We reserve the right to change technical specifica-
tions of the product without prior notice.
Info
Version October 2021
temperature
exceeds
Tel.: +49 (0)6401 9127 0
Fax: +49 (0)6401 9127 39
E-mail: info@huerner.de
HÜRNER Manual Hydr. 355 2.0 User's Manual
maxi-
17
EN