1000A AC/DC True RMS Digital Clamp-On Meter

GENERAL INSTRUCTIONS

• This device complies with IEC 61010-1, CAT II 1000V and CAT III 600V
overvoltage standards.
• To get the best service from this device, carefully read this user manual and
observe the detailed safety precautions.
• International symbols used on the device and in this manual are explained
in section 1.2.
Caution, risk of
Do not expose
electric shock
• The user must have read and understood these safety instructions.
• Failure to heed these warnings may result in serious or fatal personal injury
and/or property damage.
• Do not use or modify this device for any purpose other than for which it
was designed.
• Do not make any technical changes or modifications to the device or
defeat any safety functions.
• Use only original accessories and spare parts.
• The manufacturer disclaims liability for any damage or malfunction
resulting from failure to observe these operating and maintenance
instructions.
• The illustrations and pictures may differ from the actual device, but the
functions and required procedures remain the same.
Safety precautions
Preliminary remark
• Due to the increasing probability of high transient overvoltage in modern
power systems, electrical test equipment must meet more stringent safety
standards. Transients in electrical systems (power grid, feeders or branch
circuits) can trigger a sequence of incidents that may result in serious
personal injury. Safety must be built into test equipment to protect users
against transients.
For indoor
to rain
use only
Overvoltage
category
Brief description
Examples
CAT I
Electronic
• Protected electronic equipment.
equipment
• Equipment connected to (source) circuits in which
• Any high-voltage, low-energy source derived from
CAT II
Single-phase
• Appliances, portable tools, and other similar
loads connected
to power outlets
• Outlets and long branch circuits.
• Outlets at more than 10 metres (30 feet) from a
• Outlets at more than 20 metres (60 feet) from a
CAT III
Three-phase
• Equipment in fixed installations, such as switchgear
distribution,
including single-
• Buses and feeders in industrial plants.
phase commercial
• Feeders and short branch circuits, distribution
lighting
• Lighting systems in larger buildings.
• Appliance outlets with short connections to service
CAT IV
Three-phase
• Refers to the "origin of installation"; i.e. where low-
utility connection,
all outdoor
• Electricity meters, primary overcurrent protection
conductors
• Outside and service entrance, service drop from
• Overhead line to detached building, underground
• When using this device, the user must observe all normal safety rules
concerning:
– Protection against electrical shock.
– Protection of the device against misuse.
– For your own safety, only use the test probes supplied with the device.
Before use, check that they are in good condition.
User manual
measures are taken to limit transient overvoltage to
an appropriately low level.
a transformer with high winding resistance, such as
the high-voltage section of a photocopier.
household loads.
CAT III source.
CAT IV source.
or polyphase motors.
panel devices.
entrance.
voltage connection is made to utility power.
equipment.
pole to building, run between meter and panel.
line to well pump.