Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
2. Insert the batteries into the compartment with the correct side. The poles of the batteries must match the signs "+" and "-" on the
remote control.
3. For long time no use, take out the batteries.
4. To prevent environmental pollution, take out the used batteries and dispose safety and appropriately.
To operate the device, aim the remote controller (4) at the signal receptor (3). The remote controller (4) will operate the device at
distance 5 meters when pointing at signal receptor (3) of the device.

PROTECTIVE DEVICES

The protective device may trip and stop the appliance in the cases listed below:
1. at cooling mode: indoor air temperature is over 43°C
2. at cooling mode: room temperature is below 16°C
3. at dehumidifying mode: room temperature is below 16°C
If the device runs in cooling "K" or dehumidify "L" mode with door or window opened for a long time when relative humidity is above
80%, dew may drip down from the outlet.
The protective device will work in the following cases:
1. Restarting the device immediately after stopping work or changing the selected mode while working, you must wait 3 minutes.
2. If the plug has been removed, after restarting the device will return to the original mode, TIMER ON and TIMER OFF - must be set
again.
REMARK: there is condensing water recycling hidden within this device. The condensing water is partly kept recycling between the
condenser and build in water plate. When the water level rises to the upper level, it is raised by the float switch, then (W.F.) the full
water level indicator "R" lights up to remind you to drain the water. Please cut off the power supply, move the appliance to a suitable
place, remove the drain plug, drain water completely. After the drain, re-install the drain plug (8), or the appliance may leak and
make your room wet. If it is not drained 5 minutes after the W.F. indication on, the display will show E4.
If the appliance is placed in a position admitting drain water, you also can connect the drain pipe to the drain port to drain the water.
Drain pipe is added to kit, with inner diameter 9mm, outer diameter 12mm, material: PVC.
Troubleshooting
1) Trouble: Do not work.
Analysis:
a) maybe the protector trip or fuse is blown, please wait for 3 minutes and start again, protector device may be preventing device
from working.
c) maybe batteries in the remote controller are exhausted.
d) maybe the plug is not properly plugged in.
2) Trouble: works for a short time only
Analysis:
a) if the set temperature is close to room temperature, you can lower the set temperature.
b) maybe air outlet is blocked by obstacle. Take the obstacle away.
3) Trouble: Works but not cools
Analysis:
a) maybe door or window are open.
8