QFLEX ISOLATOR
VNET Cat5 Cable and RJ45 Connections
PIN
PAIR
COLOUR (T568B)
white/
1
2
orange
2
2
orange
white/
3
3
green
4
1
blue
white/
5
1
blue
6
3
green
white/
7
4
brown
8
4
brown
If a screen cable is used, connect the screen to LINK S
As VNET products can only supply enough
power for a single ISOLATOR, systems requiring
more than one will need an external power
supply. In this case no connection should be
made between the VNET product and the
"Ext PSU" connections of ISOLATOR, these
connections should be used for the external
power supply.
Product
Isolator
Link
Link
data +
LINK A
data –
LINK B
No Connection
power
Ext
out +
PSU +
power
Ext
out –
PSU –
No Connection
No Connection
No Connection
External supplies should produce regulated
12V DC with at least 100mA available for each
ISOLATOR that is to be supplied. Klark Teknik
can supply or recommend a suitable
power supply.
If the VNET product is connected to the
ISOLATOR via its RJ45 connector then as
described above this will automatically
connect the power from the product's LINK
port to the ISOLATOR. This is not a concern
because ISOLATOR contains circuitry to prevent
any conflict with an external power supply.
Configurations
For maximum flexibility ISOLATOR can
be used in a number of ways, below are
some examples:
1. Basic IN to OUT daisy-chaining with
additional branches as required.
LINK
LINK
LINK
LINK
ISO
ISO
IN
OUT
IN
OUT
51
Quick Start Guide
LINK
LINK
LINK
LINK
ISO
ISO
IN
OUT
IN
OUT
Network Backbone