Descargar Imprimir esta página

Vimar Eikon TACTIL 21119 Manual Del Usuario página 2

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 4
Eikon TACTIL
21119
Electronic control with N/O relay output 6 A 230 V~, can be activated locally or from different
points with remote controls or N/O push buttons, programmable monostable or bistable
operation, visible in darkness, power supply 230 V~ 50-60 Hz, to be completed with Eikon
Tactil cover plate and label.
FEATURES.
• Rated supply voltage: 230 V~, 50/60 Hz
• Mains power draw: 10 mA, 230 V~
• Indicator lights with interchangeable symbols for identification in the dark
• Touch button recalibration: 1 minute
• Operating temperature: -5°C - +35°C
CONTROLLABLE LOADS.
• Resistive loads
: 6 A.
• Incandescent and halogen lamps
: 1000 W.
• Ferromagnetic transformers
: 1000 VA.
• Electronic transformers
: 700 VA.
• Fluorescent and compact fluorescent lamps: 60 W.
• Motors
: 1.8 A cos
0.6.
• LED lamps: 60 W
If installing 2 or more switches in a single box, the loads controlled by each switch must be reduced
so that their total does not exceed the values indicated above.
OPERATION.
• Front indicator lights: always on
• Controls:
- touch control on the front; lightly place a finger on the light on the front of the device to actuate
the control.
- operation from several positions using remote control 21122 or N/O buttons (maximum range 100
m); do not use buttons with integral indicator light
- if you select the button function, the load is only active while pressing the top button.
• The buzzer is always enabled when configuring.
N.B: In the event of a mains power failure the device's relay will always go onto NO.
Each time the cover plate is installed, wait at least 1 min. for it to be recalibrated.
CONFIGURATION.
With the load/lamp switched off, press both buttons under the cover plate simultaneously. The top
button will start blinking and enter configuration phase 1:
- tap on the bottom button to change the settings of the selected configuration
- tap on the blinking top button to save the selected phase and move on to the
next phase of configuration.
If no operations are performed within 15 s, the device will exit the configuration without saving the
last phase.
CONFIGURATION
Top button LED
PHASE 1
Change brightness
1 repeated blink
PHASE 2
2 repeated blinks
Enable buzzer
PHASE 3
Enable flashing LED
with relay active to
3 repeated blinks
control load outside
the door
PHASE 4
Enable
4 repeated blinks
button
PHASE 5
Enable time
5 repeated blinks
switch
PHASE 6
Change
6 repeated blinks
timing
LED on
LED blinking
49400573B0 02 1702
SETTING
PROCEDURE
Bottom button LED
Press the bottom button to
Always on
change the brightness cycli-
at the set brightness
cally (low, medium, high)
Buzzer off
Press the bottom button to
switch the buzzer on/off
Buzzer on
Press the bottom button to
Blinking disabled
enable/disable the blinking
function
Blinking enabled
Press the bottom button to
Button disabled
enable/disable the push-
button function
Button enabled
Press the bottom button to
Timing off
enable/disable rocker button
timing
Timing on
Press the bottom button to
Initially off
start the timer; when the lower
LED is on and the desired time
has elapsed, press the top
Start of timer
button to save the timing.
(1s - 5 min)
LED off (default)
FRONT AND REAR VIEW
LED
top
button
LED
bottom
button
CONNECTIONS
L
N
For all details on possible installation architectures, please refer to SI-Installation Diagrams for the
relevant item code at www.vimar.com -> Products -> Product catalogue.
INSTALLATION
1.
3.
INSTRUCTIONS.
Connect the appliance as indicated in the "CONNECTIONS" illustration. The power circuits (L-N)
should be protected against overloading by installing a device, fuse or circuit breaker, with rated
current not exceeding 10 A.
INSTALLATION RULES.
Installation should be carried out in compliance with the current regulations regarding the instal-
lation of electrical systems in the country where the products are installed.
• The device can be installed Eikon Tactil cover plates with 2, 3 and 4 modules; use the dedi-
cated blank module art. 21041 to close the unused modules.
• When installing with a BS 5M cover plate (2+blank+2), thus on the mounting frame art. 20609,
the device cannot be installed in the central module of the mounting frame; this module
should be closed by using the blank module art. 21041 (for details, see SC-Card on www.
vimar.com -> Products -> Product Catalogue at the article code).
• On the same cover plate used for art. 21119 it is not possible to install SELV Tactil devices
(art. 21520, 21540, 21840, 21860).
REGULATORY COMPLIANCE.
LV directive. EMC directive.
Standard EN 60669-2-1.
P
N
L
L
1
N/O push-buttons
2.
4.
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com

Publicidad

loading