PARAMETER SETTING MENU (PArAM)

Press "OK" to display one of the following submenus:
Display
By default
Working time
10 s
(UorH. t)
Pedestrian working
6 s
time
(PEd. t)
Automatic closure
10 s
time
(tcA)
Opening time delay
1 s
(oPEn dELAY t IME)
Closing time delay
1 s
(cLS dELAY t IME)
Motor torque
50 %
(MOt torQUE)
Note: To adjust the limiting devices for the Ixengo S 230 V motor drive unit, use the "Working time" parameter.
Copyright © 2008 Somfy SAS. All rights reserved.
Description
Set the working time value from 3 to 180 s
Set the control panel working time value from 3 to 90 s.
Setting the automatic closure time (if tcA is active in LoGic).
Automatic closure time setting from 3 to 120 s.
Delay in starting motor 1 opening compared with motor 2, adjustable from 1 to 10 s.
Delay in starting motor 2 closing compared with motor 1, adjustable from 1 to 25 s.
Adjust the minimum amount of motor torque required to move the gate.
Motor 1 torque setting value between 1% and 99%