(1) Turn the water off at the main.
(2) Cut the plaster shield so that it extends ¹⁄₁₆" - ⅛"
from the finished wall surface.
1
Seal the wall around the plaster
shield with waterproof sealant.
Failure to seal the wall can lead
to possible water damage.
Remove the flush insert screw using a 5 mm Allen
wrench.
Remove the flush insert and seal.
Install the function block.
Tighten the function block screws using a 4 mm Allen
wrench.