Astralpool KEOPS Manual De Instrucciones Y Mantenimiento página 11

Casetas de filtración compactas
Ocultar thumbs Ver también para KEOPS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
Under no circumstances should the pump be run without having filled the prefilter with water beforehand,
otherwise this could damage the mechanical seal, which in turn will cause water leakage.
Check that the motor rotates in the right direction by observing the fan at the back of the motor through the
sight glass on the fan's cover.
Open all the valves and turn the motor on.
Self-prime the piping and wait for a reasonable amount of time for this to be completed.
4. OPERATION
4.1. FILTRATION
Turn the lever on the selector valve to the "FILTRATION" position while the pump is off. Start the pump. While
it is working it is advisable to look at the pressure gage from time to time, as the reading given will show the
filter's saturation level.
0.8 kg/cm
– 11.4 PSI:
2
normal pressure at the start of a filtration cycle
COMPACT FILTRATION HOUSING -
INSTRUCTION AND MAINTENANCE MANUAL
Fan cover
1.3 kg/cm
this pressure reading shows that the filter should be backwashed
CORRECT
INCORRECT
– 18.5 PSI:
2
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

RamsesRamses upKefren

Tabla de contenido