Astralpool 66570 Manual De Instalación, Operación Y Mantenimiento página 23

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING: Risk of unit damage. Clean all piping prior to connecting and starting the
unit up.
WARNING: Risk of unit damage. Install a 130 m filter before the water inlet.
WARNING: It is highly recommended to install a regulation valve on the water inlet
to adjust the water jet height.
WARNING: It is highly recommended to install a shut-off valve outside the niche in
order to make maintenance tasks easily.
WARNING: Depending on the switches' number installed at the same manifold, and
depending on the installed nozzle, a relief regulation could be needed to keep jets
height stable.
2.4.2
Electric
WARNING: Risk of unit damage. The unit working needs a control system which
keeps one of the valves activated (ornamental outlet or relief outlet). Two valves
cannot be activated at the same time nor disabled at the same time during normal
working. When the fountain is not working, valves must be disabled.
WARNING: Risk of unit damage. Install a 2-A fuse on the electrical panel to prevent
power surges on 24VDC Brown and yellow-green wires.
WARNING: Risk of unit damage. Check that all IP68 connectors are properly sealed
WARNING
WARNING
WARNING
and that they prevent water getting through. Electrical components may become
damaged by flooding and the unit could lose its warranty.
2) Connect electrical wiring to the unit (⑤
Wire
Color
Blue
Brown
Green-
yellow
Voltage
0 V
Common reference for outlets.
+24 V
Top ornamental outlet activation ①
DC
+24 V
Side relief outlet activation (③
DC
⑤ ).
Function
① .
③ )
23

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

66572

Tabla de contenido