18"
(45.7 cm)
1"
(2.5 cm)
8-1/2"
(21.6 cm)
2-1/2"
(6.4 cm)
Product Information
Applicable product:
Drop-in
Tile flange, left drain
Tile flange, right drain
Fixture*:
Bathing well:
Basin area, bottom
55" (139.7 cm) x 21" (53.3 cm)
Basin area, top
65" (165.1 cm) x 26" (66 cm)
Weight
71 lbs (32.2 kg)
To overflow:
Water depth
15" (38.1 cm)
Capacity
72 gal (272.5 L)
* Approximate measurements for comparison only.
Drop-in cutout dimensions:
70-1/2" (179.1 cm) x 34-1/2" (87.6 cm)
V
Pump: 1-speed
120
Heater: 1.5 kW
120
Minimum access panel
pump/control (required):
1012979-1-B
72" (182.9 cm)
1/4" (6 mm)
2-7/8" (7.3 cm)
3" (7.6 cm)
K-1157-H
K-1157-LH
K-1157-RH
Hz
A
60
7.5
60
12.5
20" (50.8 cm) W x
15" (38.1 cm) H
No change in measurements if connected with drain
illustrated. (K-11677 or K-11677M)
Pump/Control Access
(If Apron Is Not Used)
20" (50.8 cm) W x
15" (38.1 cm) H
20-1/8"
18-5/8"
(51.1 cm)
(47.3 cm)
Required Electrical Service (2 required)
Two dedicated circuits required, each protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
Heater
Locate the outlets behind the whirlpool and within 24" (61 cm)
of the pump and heater.
Notes
Install this product according to the installation guide.
Floor support under this product must provide for a minimum of
39 lbs/square foot (189 kg/square meter) loading.
The apron must be installed before the finished floor and wall
materials are installed.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions
are nominal.
2
1-1/4"
1-1/2"
(3.2 cm)
(3.8 cm)
Tile Flange
Drop-in Rim
Detail
Detail
36" (91.4 cm)
1-1/2" OD
120 V, 15 A, 60 Hz
120 V, 15 A, 60 Hz
Kohler Co.

Publicidad

loading

Este manual también es adecuado para:

K-1157-lhK-1157-rh