Jung JLA-e 5/12 G Manual De Instrucciones página 57

Ocultar thumbs Ver también para JLA-e 5/12 G:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 67
Ventilation fault
Fault
Low pressure in the ventilation
system, error in the pump or in
the electrolyte circulation system.
If the pressure values are not
corrected again within one minute,
the charging current I1 is reduced
to 80% in the main charging
phase and the pump is no longer
switched on.
Low pressure in the ventilation
system, error in the pump or in
the electrolyte circulation system.
If the pressure values are not
corrected again within one minute,
the charging current I1 is reduced
to 80% in the main charging
phase and the pump is no longer
switched on.
More than 5 malfunctions in the
electrolyte circulation system
(pressure either too high or too
low) during the charging cycle;
the loading current I1 is reduced
to 80% in the main charging
phase and the pump is no longer
switched on.
Leaky point in the electrolyte
circulation system; after switching
off the pump, the pressure drops
rapidly.
Blockage of the charging device
due to malfunctions in the electro-
lyte circulation system.
© JUNG Hebe- und Transporttechnik GmbH
Electrically driven trolleys JLA-e 5/12 G with stroke and JLA-e 15/30 G with stroke
E5x Cause
• Error in the connection of the electrolyte
E51
circulation system or faulty pump
• Clogged or kinked electrolyte circulation
E52
system
• Pressure loss in the ventilation system
• Clogged or kinked electrolyte circulation
E53
system
• Pressure loss in the electrolyte circulation
E54
system
• Blockage of the charging device due to
exceeding the set number of errors E51,
E52, E54
E55
• Error in the electrolyte circulation system
or faulty pump
• Clogged or kinked electrolyte circulation
tubing
Elimination
• Check the electrolyte circulation system
and the pump
• Check the electrolyte circulation system
• Check the electrolyte circulation system
and the pump
• Check the electrolyte circulation system
and the pump
• Check the ventilation pipelines and pump
• Charging device must be unlocked by the
service technician
- 57 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Jla-e 5/30 g

Tabla de contenido