Dometic DM 100 Instrucciones De Montaje página 33

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 56
All manuals and user guides at all-guides.com
DoorLock DM100, DP100
9.3
Calibrate the card reader (DP100 only)
The card reader of the DP100 has to be calibrated before use.
➤ Loosen the screw for the battery compartment (fig. 7 1., page 9).
➤ Remove the battery compartment cover (fig. 7 2., page 9).
➤ Disconnect the cable for the power supply from the control unit (fig. 7 3.,
page 9).
➤ Connect the calibrator to the calibration connector (fig. 7 4., page 9).
I
NOTE
Make sure that there are no cards and metal objects in the sur-
rounding area of the card reader.
➤ Connect the cable for the power supply to the control unit (fig. 7 5.,
page 9).
✓ The green LED lights up for one second. Then both LEDs light up for one
second. After 5 – 10 seconds, both LEDs light up simultaneously. The
card reader can be calibrated.
➤ Move the RFID transponder to the card reader.
➤ If both LEDs turn off, remove the RFID transponder from the card reader.
✓ After no more than three seconds, one or several LEDs light up:
LED
Both LEDs light up.
Red LED lights up.
Green LED lights up.
➤ Remove the calibrator from the calibration connector (fig. 7 6., page 9).
➤ Replace the battery compartment cover (fig. 7 7., page 9).
➤ Affix the battery compartment with the screw (fig. 7 8., page 9).
➤ Move an RFID transponder to the card reader.
✓ The green LED lights up. The door lock can be programmed.
EN
Description
The calibration was not successful.
➤ Move the RFID transponder to the card reader
again and check the result in this table.
The calibration was not successful.
➤ Repeat the entire calibration process.
The calibration was successful.
Fitting the door lock
33

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Dp 100

Tabla de contenido