Bathroom Exhaust
Blower Fan
MODELS: 695-220 & 696N-220
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off at
service panel and lock service panel to prevent power
from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
B. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must
be marked as appropriate for the application.
F. NEVER place a switch where it can be reached from a tub
or shower.
Designed to be mounted in the ceiling or in a standard
2" x 4" wall.
WARNING: To reduce the risk of fire or electric shock, do
not use this fan with any solid-state speed control device.
WARNING: To reduce the risk of shock, disconnect power
before servicing.
NOTE: Not for use in kitchens.
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
SWITCH
BOX
WHITE
BLACK
220VAC, 50/60 Hz
HOUSE POWER
INSTALLATION OF HOUSING
Rough Opening:
8
Housing Size:
7
NOTE: Refer to Figure 1. Remove motor plate from
housing before mounting. Insert screwdriver between motor
plate and side of housing with duct collar. Gently pry the
housing away from the motor plate while pulling up on the
motor plate to disengage the plate from the housing.
1. With nails or screws, secure (but do not tighten) the
housing to the ceiling or wall through the two (2)
keyhole slots in the mounting tabs.
NOTE: Prior to completely tightening, adjust the housing
so that the outer edge will remain
the finished ceiling or wall. For the grille to fit properly, the
housing must not extend outside the finished wall surface.
2. Secure discharge adapter over flanges on housing and
connect ducting to discharge.
WIRING
IMPORTANT: Be certain all wiring complies with local
codes and the unit is properly grounded.
1. Refer to Figure 2. Run power leads from the wall switch,
timer switch or speed control switch to the unit.
2. Using approved wire connectors, connect supply wires to
fan wires: black to black and white to white. Connect
ground wire (green or bare) to the green ground screw in
the fan's junction box.
PLUG INSERTS
INTO HOUSING'S
RECEPTACLE
TABS
SLOTS
FIGURE 1
BLACK
WHITE
FAN
HOUSING
FIGURE 2
1
1
" long by 7
" wide
4
4
3
1
7
" x 8
" x 3
"
16
16
8
1
1
" to
" recessed from
8
4

Publicidad

loading

Resumen de contenidos para NuTone 695-220

  • Página 1 READ & SAVE THESE INSTRUCTIONS! PLUG INSERTS Bathroom Exhaust INTO HOUSING'S RECEPTACLE Blower Fan TABS MODELS: 695-220 & 696N-220 IMPORTANT SAFETY INSTRUCTIONS SLOTS WARNING: TO REDUCE THE RISK OF FIRE, FIGURE 1 ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Página 2 DUCTING 1. Refer to Figures 3 and 4. Run 3" round duct from the discharge opening to the outside of the home. INSTALLING THE FAN AND GRILLE 1. Refer to Figure 1. Insert the two tabs on the motor plate into slots in housing.
  • Página 3 VENTILADOR ASPIRANTE ENCHUFE LOS INSERTOS EN EL PARA CUARTOS DE BAÑO RECEPTACULO DE LA CAJA MODELOS: 695-220 y 696N-220 LENGÜETAS INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIO, SACUDIDA ELECTRICA O LESIONES A LAS PERSONAS, OBSERVE LO SIGUIENTE: A.
  • Página 4 CANALIZACION 1. Vea las Figuras 3 y 4. Pase el conducto redondo de 3 pulgadas desde la abertura de descarga hasta el exterior de la casa. INSTALACION DEL VENTILADOR Y DE LA REJILLA 1. Vea la Figura 1. Inserte las dos lengüetas en la placa del motor por las ranuras de la caja.

Este manual también es adecuado para:

696n-220