Attention! The fitting must be installed, flushed
and tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Mount the S - unions and align them.
3. Fasten the mixer with the washers.
Large differences in pressure between the hot and
cold water supply should be balanced.
Operation
The mixer is actuated by lifting the lever head.
Swivel to the left = hot water, swivel to the right =
cold water.
33144000/33143000: The flow is changed from
bath to shower function by pulling the knop at the
upper side of the spout. After shutting off the water
flow, the mixer returns automatically to the bath
function.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G ½":
Rate of flow 0.3 MPa:
Back flow and vacuum breaker
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work - Flow limiter in handshower isn't
6
English
Hansgrohe single lever mixers can be used tog-
ether with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0.15 MPa.
To adjust the hot water limiter on single lever
mixers, please see page 15.
No adjustment is necessary when using a conti-
nuous flow water heater.
Attention!
The non return valves must be checked regularly
according to DIN EN 1717 in accordance with
national or regional regulations (at least once a
year).
Spare parts (see page 3)
1
1.1 screw cover
2
3
4
5
max. 1 MPa
6
0.1 - 0.5 MPa
7
1,6 MPa
8
9
max. 80° C
10
65° C
11
150 ± 16 mm
12
cold right -
13
hot left
approx. 20 l/min
Cause
- Shower filter seal dirty
- Filters dirty
- Non return ralve didn't move
back
- Cartridge defective
- Cartridge defectiveSedimentati-
on
- Hot water limiter incor-rectly set - Set hot water limiter
removed
- Filter are dirty
- Non return valve didn't move
back
handle
flange
nut
cartridge, assy
locking screw
escutcheon Ø 68 mm
ball S - unions (2)
noise reduction (2)
aerator cpl. (10)
selector assy
diverter knob
non return valve DW 15 (10)
hose connection
Remedy
- Clean filter seal between sho-
wer and hose
- Clean the filter/exchange filter
- Exchange non return valves
- Exchange cartridge
- Exchange cartridge
- Remove flow limiter
- Clean the filter/exchange filter
- Exchange non return valves
33092000
96338000
96656000
96690000
92730000
96059000
96467000
94140000
96429000
13956000
94077000
96466000
94074000
96044000