A controller with analog outputs is required for the analog setpoint specification of the operating
pressure of the inverting cap. We recommend the CPX-E-CEC, for example. (Order number 8115865)
If no control is available, the operating pressure of the inverting cap must be set manually when
switching on.

8.3 Manual setting of the operating pressure of the inverting cap

1. Set the system pressure to 6 bar.
3. Use the arrow keys to set the pressure 0.08 - 0.1 bar.
Regulation will take place reliably at 0.1 bar.
Information
If less than 0.1 bar is to be set, the value must be set to 0.1 bar and then lowered to 0.08 bar. It is
not possible to set the setpoint value below 0.08 bar by manual input.
© Festo Didactic 8116523
2. Press the Edit pushbutton on the proportional valve until 'Frc'
(Force) appears on the display.
Then hold Edit pressed for approx. 3 seconds until the value
flashes.