025905 BDI-S 30 3210 (Schuko).qxp_025905 BDI-S 2 30 14.03
Circuit breaker safety plug
BDI-S 2 30
Caution: Important safety precautions!
– Its use under other environmental conditions, e.g.
ambient temperatures below -25°C and above
40°C, flammable gases, solvents, vapors, dust,
relative humidity above 80% and moisture should
be avoided at all costs.
– If it can be assumed that risk-free use is no longer
possible, stop using the safety plug immediately
and make it secure against unintentional use.
Risk-free operation can no longer be assumed if it
fails the function test, exhibits visible damage or is
damaged in transit or through storage under
unfavourable conditions.
– Servicing and repairs may only be carried out by
authorised, qualified persons. Only genuine manu-
facturer's spare parts may be used for replace-
ment purposes.
Description of function
The electronic safety plug is a highly sensitive, trans-
ferable item of equipment which provides protection
against hazardous accidents resulting from physical
contact with live leads or parts. If a potential risk aris-
es, the adapter responds even at low leakage
currents (minimum 30 mA), interrupting the power
supply within a few milliseconds and assuring safe,
swift protection between the power socket and the
connected appliance.
The safety plug is intended to be used as a fixed
connecting plug and permanent attachment for
frequently used electrical appliances. Some models
are already cable-connected. Point 1 of commission-
ing does not apply in such cases.