025905 BDI-S 30 3210 (Schuko).qxp_025905 BDI-S 2 30 14.03
Directions for use
1. Engage a qualified electrician to connect the safe-
ty plug to the appliance or extension cable in place
of the normal plug, in accordance with the applica-
ble regulations.
Ensure without fail that the green/yellow lead is
connected to the screw marked with the
symbol.
2. Plug the safety plug directly into a wall socket on-
ly. Before doing so, switch off the connected elec-
trical appliance.
3. Switch on the safety plug by pressing the RESET
button. A red indicator must appear in the window
above the RESET button.
4. Now carry out a function test by pressing the
TEST button. A distinct switching noise must be
heard and the red indicator must disappear.
5. The safety plug must not be used if the switching
noise is not heard and the red indicator continues
to appear in the window.
6. If the test proves successful, press the RESET
button again. The safety plug is now ready for use.
Note:
From time to time, carry out a function test,
press the Test button and perform the procedure
described above.
After a power cut, switch on the safety plug
again.
The safety plug is not suitable for appliances
which may give rise to consequential damage if
disconnected from the power supply for a
prolonged period of time (e.g. refrigerators,
freezers, etc.).