HALFEN HTA, HTA-CE, HZA, HZA DYNAGRIP
HALFEN Cast-in channels HTA-CE
Dimensioning according to
EOTA TR 047 / EN1992-4 based on
European Technical Assessment
ETA-09/0339 and ETA-16/0453.
1. Type identifi cation / General information
Nail hole
HALFEN Channels are supplied with a combi (foam) strip
fi ller and with punched holes for nailing to the formwork.
Excessive combi (foam) strip fi ller has to be cut fl ush at
the channel ends. When fi xing to the formwork make sure
that the HALFEN Channel type (profi le, material, length)
and its position is as specifi ed in the respective drawing.
Fix channels securely so that they will not be displaced
during the concrete pour and remain fl ush with the surface
of the formwork. If the formwork is unsuitable for nailing,
please select an alternative fi xing method.
2. Preparations
2.1
2
Anchor
Combi strip fi ller
!
HALFEN Cast-in channels HZA
General Certifi cates of Approval; DIBt Berlin:
Z-21.4-145
Z-21.4-1691
HZA
HZA
41/22
DYNAGRIP
1.1
Type identifi cation:
On the inside of the profi le back.
Additionally on the side of the channel.
To avoid rust forming on stainless steel
HALFEN Channels: Remove steel packing straps
immediately on delivery and store separately
with suffi cient distance to other metals. Avoid
surface damage and contamination caused by
contact with carbon steel. Always store the
cast-in channels in dry, covered and properly
ventilated environments.
2.1
Select HALFEN Cast-in channel acc. to the design
documents.
© 2019 HALFEN · INST_HTA 01/19 · www.halfen.com