Technical Data; Use; Periodic Maintenance; General Maintenance - Rothenberger RP PRO III Manual Del Usuario

Ocultar thumbs Ver también para RP PRO III:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
2

Technical data

Voltage ............................................... 230 V, 50 Hz
Nominal power of the motor .............. 1.3 Kw
Rated current ..................................... 6 A
Protection class ................................ IP20
Maximum pressure ............................ 40 bar
Nominal flow: max. ............................ 6 l/min
Net weight of device: ........................ 16 Kg
Total dimensions of device: ............... 380 x 290 x 300 mm
Supply water: .................................... clean freshwater, Glycol, Tyfocor, Maximum temperature: 40ºC
High pressure hose: .......................... Ø int. 1/4", 1.2 m. length
Lubricant: ........................................... oil for 4-stroke engines SAE 15W/40
Noise level: ....................................... no higher than 90 dB (A)
3

Use

Pressure testing of seals on piping systems and vessels used in all types of installations.
Hydraulic, heating, steam, refrigeration, oil, spraying installations, solar thermal systems, etc.
Production of boilers (verification of tightness of coils) and pressure recipients or tanks, filling of circuits.
4

General maintenance

Before connecting the pump to electric sockets and water supplies:
a. Carefully check the condition of the high pressure hose and the cord of the plug. If necessary,
replace with new ones.
b. Check the water filter (No. V121M37 - C Spare Parts). Clean it and replace it if necessary.
If the device is to be stored for a long period of time, it is recommendable to empty the water remaining
in the internal circuits
Avoid storing the equipment in very cold places where there is a risk of freezing
Keep the water filter clean and in good condition
If the equipment is used with antifreeze agents such as Glycol, Tyfocor, etc. use the device with clean
freshwater to clean out the internal circuits
5

Repair and replacement of parts

There is a maintenance Kit for the most accessible set of sealing gaskets (cod. R6.1186), which
enables the replacement of the most commonly worn or eroded gaskets and prologues the power
pump's lifespan.
The replacement of parts, servicing of the pump and electrical inspection should only be carried out by
official Service Centres.
6
Operating instructions
1. Open the master bleeder of the piping system or vessel to be drained (i.e. Fig B On appliance)
2. Connect water inlet hose to hose connection on side of appliance (Fig F option A or B)
Option A: Direct from water mains (Min pressure 1 BAR)
Option B: Use Clean water from water storage container which should be placed no more
than 1 meter MAX below pump level
3. Connect high pressure hose, threaded ½" male end to ½" female connection beside control
valve V2 on appliance and ½" female connection on high pressure hose to appropriate fitting
on system to be tested
4. Turn control valve V2 Anticlockwise fully to OPEN
Turn control valve V1 Anticlockwise fully to –BAR
5. Plug appliance into mains (Fig E On appliance). Power must be 230V 50 Hz * OR on 110V
APPLIANCES USE A 3KVA TRANSFORMER ONLY!
16
(110 V.), single-phase
ENGLISH

Publicidad

Tabla de contenido
loading

Tabla de contenido