j)
Please keep this manual available for future
reference. If this device is passed on to a third party,
the manual must be passed on with it.
k)
Keep packaging elements and small assembly parts
in a place not available to children.
REMEMBER! When using the device, protect
children and other bystanders.
2.3. PERSONAL SAFETY
a)
Do not use the device when tired, ill or under the
influence of alcohol, narcotics or medication which can
significantly impair the ability to operate the device.
b)
The device is not designed to be handled by persons
(including children) with limited mental and sensory
functions or persons lacking relevant experience
and/or knowledge unless they are supervised by
a person responsible for their safety or they have
received instruction on how to operate the device.
c)
The device can be handled only by physically fit
persons who are capable of handling it, properly
trained, familiar with this manual and trained within
the scope of occupational health and safety.
d)
To prevent the device from accidentally switching on,
make sure the switch is on the OFF position before
connecting to a power source.
e)
Do not wear loose clothing or jewellery. Keep hair,
clothes and gloves away from moving parts. Loose
clothing, jewellery or long hair may get caught in
moving parts.
f)
The device is not a toy. Children must be supervised
to ensure that they do not play with the device.
2.4. SAFE DEVICE USE
a)
Do not overload the device. Use the appropriate
tools for the given task. A correctly-selected device
will perform the task for which it was designed better
and in a safer manner.
b)
Do not use the device if the ON/OFF switch does not
function properly (does not switch the device on and
off). Devices which cannot be switched on and off
using the ON/OFF switch are hazardous, should not
be operated and must be repaired.
c)
Disconnect the device from the power supply
before commencement of adjustment, cleaning and
maintenance. Such a preventive measure reduces
the risk of accidental activation.
d)
When not in use, store in a safe place, away from
children and people not familiar with the device who
have not read the user manual. The device may pose
a hazard in the hands of inexperienced users.
e)
Keep the device in perfect technical condition.
Before each use check for general damage and
especially check for cracked parts or elements and
for any other conditions which may impact the safe
operation of the device. If damage is discovered,
hand over the device for repair before use.
f)
Keep the device out of the reach of children.
g)
Device repair or maintenance should be carried out
by qualified persons, only using original spare parts.
This will ensure safe use.
h)
To ensure the operational integrity of the device, do
not remove factory-fitted guards and do not loosen
any screws.
i)
When transporting and handling the device between
the warehouse and the destination, observe the
occupational health and safety principles for manual
transport operations which apply in the country
where the device will be used.
EN
j)
Do not touch articulated parts or accessories unless
the device has been disconnected from the power
source.
k)
Do not move, adjust or rotate the device in the
course of work.
l)
Do not leave this appliance unattended while it is in
use.
m)
Clean the device regularly to prevent stubborn grime
from accumulating.
n)
The device is not a toy. Cleaning and maintenance
may not be carried out by children without
supervision by an adult person.
o)
When replacing filters in the device, wear protective
gloves, goggles and a mask to avoid contact with
residual fumes, which may be toxic.
ATTENTION! Despite the safe design of the device
and its protective features, and despite the use of
additional elements protecting the operator, there
is still a slight risk of accident or injury when using
the device. Stay alert and use common sense when
using the device.
3. USE GUIDELINES
The device is designed to extract the fumes generated
during soldering.
The user is liable for any damage resulting from
unintended use of the device.
3.1. DEVICE DESCRIPTION
8
1
9
2
3
4
5
6
1.
Front cover
2.
Carbon filter/vapour inlet
3.
Frame knob
4.
Base
5.
Main switch
6.
Power socket and fuse socket
7.
Rear cover
8.
Carbon filter access opening
9.
Vapour outlet
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The temperature of environment must not be higher than
43°C and the relative humidity should be less than 85%.
Ensure good ventilation in the room in which the device
is being used. There should be at least 10 cm distance
between each side of the device and the wall or other
objects. The device should always be used when positioned
on an even, stable, clean, fireproof and dry surface, and
be out of the reach of children and persons with limited
mental and sensory functions. Position the device such that
you always have access to the power plug. The power cord
connected to the appliance must be properly grounded
and correspond to the technical details on the product
label!
25.03.2019
8
ASSEMBLING THE APPLIANCE
1.
Unpack the fume extractor.
2.
Please unpack the device carefully.
3.
Check that the unpacked fume extractor is not
damaged. In the event of visible damage, contact
the manufacturer immediately.
4.
Place the carbon filter in the fume extractor.
5.
Plug the power cord into a socket.
3.3. DEVICE USE
1.
Position the fume extractor so that the soldering
fumes are drawn by the air whirl.
2.
To set the right fan angle, loosen the frame fixing
by unscrewing the knob. After reaching a satisfactory
angle, gently screw the frame fixing back using the
knob.
3.
Connect the fume extractor to the power source.
4.
Set the main switch position to "I".
5.
When you have finished work, set the main switch
position to "0".
PLEASE NOTE: Make sure that nothing blocks or hinders the
rotation of the fan.
Carbon filter replacement
7
PLEASE NOTE: In the course of use, the filter in the air
extraction system gradually becomes contaminated and
stops extracting soldering fumes effectively.
The filter should be replaced once a month or if dust can
be seen on it.
Before replacing the filters, make sure that the fan has
stopped.
Important!: do not dispose of used filters together with
ordinary garbage. They must be disposed of in accordance
with the regulations in place in the location where the
device is used.
Before replacing the filter, make sure that the fume
extractor is turned off and the fan is not rotating.
Filter replacement:
•
Remove the used filter from the fume extractor
through the filter replacement access opening.
•
Insert the new filter into the fume extractor through
the filter replacement access opening
3.4. CLEANING AND MAINTENANCE
a)
Unplug the mains plug and allow the device to cool
completely before each cleaning, adjustment or
replacement of accessories, or if the device is not
being used.
•
Wait for the rotating elements to stop.
b)
Use only non-corrosive cleaners to clean the surface.
c)
After cleaning the device, all parts should be dried
completely before using it again.
25.03.2019
EN
d)
Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
e)
Do not spray the device with a water jet or submerge
it in water.
f)
Do not allow water to get inside the device through
vents in the housing of the device.
g)
Clean the vents with a brush and compressed air.
h)
The device must be regularly inspected to check its
technical efficiency and spot any damage.
i)
Use a soft cloth for cleaning.
j)
Do not use sharp and/or metal objects for cleaning
(e.g. a wire brush or a metal spatula) because they
may damage the surface material of the appliance.
Fuse replacement
PLEASE NOTE! The fuse should be replaced by a specialist!
1)
Disconnect the device from power supply.
2)
Disconnect the power cord and remove the fuse
holder.
3)
Replace the fuse, making sure that the parameters
are the same.
4)
Reinstall the fuse socket.
PLEASE NOTE! To avoid damage to the fuse socket,
do not use excessive force when removing and
installing the fuse socket.
9