Installation; Hoses And Connections; Lubrication; Operation - Chicago Pneumatic Lubricator 43 Instrucciones De Seguridad Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
Lubricator 43, Lubricator 1300
Safety label
Machine type
A.
Maximum permitted compressed air pressure
B.
C.
The warning symbol together with the book
symbol means that the user must read the
safety and operating instructions before the
machine is used for the first time.

Installation

Hoses and connections

Compressed air source
A.
Water separator (optional)
B.
C.
Lubricator
Max. 3 m (10 ft) compressed air hose between
D.
the lubricator and the pneumatic machine.
The maximum permissible air pressure, 20 bar (e)
(290 psi), must not be exceeded.
Blow any impurities out of the compressed air
hose before connecting it to the lubricator.
For the Lubricator 43 and Lubricator 1300 a hose
with a minimum internal diameter of 20-25 mm
(
3
-1 in.) must be used.
4
9800 1218 90 | Original instructions
All manuals and user guides at all-guides.com
Safety and operating instructions
There is a an arrow on the lubricator to indicate
the correct direction of air flow. When connecting
the lubricator, make sure that the arrow points in
the same direction as the air flow.

Lubrication

The lubricant is important for the pneumatic
machine s function and has a great impact on the
useful service life. To guarantee good lubrication,
the length of the air hose between the lubricator and
the pneumatic machine must not exceed 3 meters.
Viscosity range
Temperature °C (°F)
+15 to +50
(+59 to +122)
-20 to +15
(-4 to +59)
For the correct recommended lubrication oil, refer
to the Safety and operating instruction for the
pneumatic machine used together with the
lubricator.
Oil adjustment
Lubricator 43 and Lubricator 1300 are delivered with
the oil dosage screw in the fully open position. The
oil dosage screw can be turned through a total of
four complete turns. It is steplessly adjustable.
To adjust the oil dosage, do the following:
Use a screwdriver to turn the oil dosage screw.
Clockwise reduces oil flow.
Anticlockwise increases oil flow.
Never remove the spring pin. If the oil dosage
screw become loose, the spring pin will prevent
it from blowing out of the lubricator.
Check the exhaust port of the pneumatic machine
to see that sufficient lubrication is being
exhausted.

Operation

Operating

Filling the lubricator with oil
Always top up the lubricator with oil at the start of
the shift.
Viscosity
ISO VG 46–68
200-300 SUS
ISO VG 22–32
100-150 SUS
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lubricator 1300

Tabla de contenido