3.3
Parameter setting and display
To go into the parameter menu:
– from the selected mode (eg. WINTER)
– press the buttons
<
and
o
same time until "tS" (installer) appears on the 2 digits of the
display which alternate with "0.1" (parameter number) and
a "2" (set value)
– press the button
>
to scroll up the list of parameters and
then
<
to scroll down the list
holding the buttons
>
NB:
scrolling movement.
– once the required parameter has been reached, press the
button
o
to confirm and access the set value which will
then flash and can then be modified
3.4
List of parameters
Type
No.
Description
Index showing boiler power in kW
tS
0.1
1 = 25; 2 = 30
Hydraulic configuration
0 = rapid
tS
0.2
1 = hot water tank with thermostat
2 = hot water tank with sensor
3 = two programmer
Gas Type Configuration
tS
0.3
0 = G20; 1 = G31
Combustion configuration
tS
0.4
0 = sealed chamber with combustion control
1 = open chamber with smoke probe
tS
0.7
Ignition power
tS
0.8
External sensor value correction
72
All manuals and user guides at all-guides.com
(approximately 5 seconds) at the
or
<
increases the speed of the
CONFIGURATION
– to modify the value in the permitted range, press the but-
tons
>
to increase it or
<
to decrease it
– once the required value has been reached, press the button
o
to confirm.
When all the parameter modifications have been made, exit
the parameter menu by pressing and holding down the but-
tons
<
and
o
at the same time
splayed.
Range
1 .. 2
0 .. 3
0 .. 1
0 .. 1
0 .. 40
-5 .. +5
EN
until the initial screen is di-
Unit of
measu-
Step
Default
rement
-
1
1 or 2
-
1
0
-
1
0
-
1
0
-
1
0
°C
1