COMMISSIONING

3.1

Preliminary operations

Before commissioning the appliance, check that:
– the type of gas is correct for the appliance
– the gas isolation valves for the heating system and the wa-
ter system are open
– the system pressure as shown on the pressure gauge when
the system is cold , is between 1 and 1.2 bar
– the pump impeller rotates freely.
3.2

Before commissioning

After having carried out the preliminary operations, perform
the following to start the boiler:
– set the main system switch to "ON"
ON
– the type of gas for which the boiler has been calibrated, "nG"
(methane) or "LG" (LPG,) will appear followed by the power.
After this the correct representation of the symbols will be
checked and finally "- -" will appear on the display
– press the button
s
once for at least 1 second to select
"SUMMER mode"
. the value of the delivery sensor de-
l
tected at that moment will appear on the display
3.2.1

Self-calibrating procedure

Carry out the "Automatic self-calibrating procedure" as fol-
lows:
– press and hold down the buttons
for approximately 12 seconds until the flashing symbols
and
n
appear on the display
All manuals and user guides at all-guides.com
Fig. 29
o
and
>
at the same time
l
– as soon as the symbols begin to flash, release the buttons
o
and
>
and press the button
– the "Automatic self-calibrating procedure" starts
– open one or more than one hot water tap
– the values flash on the display: "99" (maximum value), fol-
lowed by an "intermediate value" and finally "00" (minimum
value)
The operator must wait for approximately 15 minutes for the
"self-calibrating procedure" to end and the message "SUM-
to reappear on the display Once the procedure
MER mode"
l
has terminated:
– close the taps opened previously and check that the ap-
pliance shuts down.
if there is a fault, the message "AL" will appear on the display
followed by the fault code (eg. "06" - no flame detected).
m
CAUTION
To restore the start conditions press and hold the
button
o R
for more than 3 seconds. This opera-
tion can be performed up to a maximum of 6 times
without the "self-calibrating procedure" being inter-
rupted.
– press the button
s
once to select "WINTER mode"
value of the heating water temperature detected at that mo-
ment will appear on the display
– adjust the air thermostat and check that the boiler starts
and operates correctly
– carry out the procedure"Chimney sweep function", to check
the mains gas pressure, detect the combustion parameters
and to measure the combustion efficiency required by legi-
slation in force..
s