Filter Replacement - Guardian Technologies AC9200 Instrucciones De Uso Y Cuidado

Ocultar thumbs Ver también para AC9200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FILTER REPLACEMENT

The "Replace Filter" indicator will light when it is time to replace your filter. Depending on usage and
environmental conditions the filters will last approximately 6 months and should be replaced at the
same time. The filter will turn from white to gray/black when it is dirty and needs replacing. It is
important to maintain and change the filters to continue to optimize the performance of the air purifier.
IMPORTANT: DO NOT wash and re-use the filters. Please contact Customer Service or visit our
website www.guardiantechnologies.com to purchase a replacement filter.
REMOVE AND REPLACE FILTER
1. Turn off and unplug the unit.
2. Gently pull the top of the
3. Remove the filters by
front panel and lift
pulling the side tabs.
from base.
5. Reinstall the Pre-filter Screen by inserting into the tabs
on the body of the unit.
Note: The 2 center tabs on the screen should face outwards,
and the arrows located on the side should point up.
6. Return the front panel: First insert the front panel bottom hooks then close the front panel.
Make sure the magnetic closure is secure.
Note: Proper filter and front panel installation is necessary for unit to turn on.
RESET INDICATOR LIGHT
After the filter OR UV-C bulb has been replaced you will need to reset the indicator light.
1. The reset button is located IN the side grill (See INSET)
2. To reset the light, use a paper clip or flat tipped object, insert it into the lower left portion of the
grill and push the red button with the tip.
3. Check to make sure light is off when unit is restarted.
E-8
4. Insert the new filters into the
unit – consult the arrows on the
filters for correct installation
direction. The proper installation
sequence should be
1. Carbon Filter 2. Filter
INSTALLING & REMOVING UV-C BULB
UV Bulb Replacement Indicator: The UV light on the display will flash when its
time to replace the UV bulb.
1. Pull and remove the front
cover and all filters.
3. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and
twisting the bulb 1/4 turn. Remove from unit.
Bulb is NOT visible until the UV-C
SHIELD has been removed.
4. The UV-C Bulb is reinstalled by reversing the process in Step 3.
5. Re-attach the UV-C Shield.
6. Reset the UV light according to the "Reset Indicator Light" instructions (E8).
Replacement bulb: LB9200
IMPORTANT: The UV-C Bulb should be replaced every 10 - 12 months depending on use.
2. After removing the filters, use a Philips
head screwdriver to remove 2 screws
and detach the UV-C Shield.
TWIST BULB 1/4 TURN
TO REMOVE BULB
E-9

Publicidad

Tabla de contenido
loading

Tabla de contenido