2. Place the lifting device on a load with a smooth, airtight surface, e.g. a metal sheet.
3. Apply suction to the load.
If this vacuum is not reached, check the following:
1. Check the status of the sealing lip and the screw connections.
2. Clean the dust filter with a brush.
9.5 Cleaning the Dust Filter
DANGER
Falling load.
Serious injury or death!
Depending on the dust load, clean the dust filter at least once a week.
1. Switch off the vacuum generator.
2. Carefully tilt the lifting device onto its side.
3. Clean the dust filter (10) with a brush.
9.6 Cleaning the lifting device
The lifting device must only be cleaned with an agent containing active tensides (pH-neutral).
9.7 Replacing Sealing Lip
1. Carefully tilt the lifting device onto its side.
52700015 / 52700016 / 52700017 / 52700018 / 52700019 / 52700020
Maintenance
37 / 41