SEELEY INTERNATIONAL TBA Serie Manual Del Propietário página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 64
MAINTENANCE
PRE-SEASON SERVICE
•Turn off the power supply to the air cooler
•Remove the pad frames as shown.
•Ensure the power switch in the cooler is off.
•Gently wash the pads to remove any dust
build up during the winter period. If the pads
are in poor condition, replace them.
IMPORTANT: Do not damage the pads with
high pressure water spray.
•Replace the bleed system if it was removed
during previous maintenance and ensure the
o-ring is fitted. (If the cooler is fitted with a
drain valve this will not be necessary as it will
automatically close when the cooler turns
on).
•Turn on the power switch inside the cooler.
•Turn on the water and then the power.
•Re-fit the pad frames and run the cooler.
WARNING: Do not run the air cooler with
the pad frames removed.
REMOVAL OF PAD FRAMES
To remove a pad frame, insert a flat screw
driver tip into the slot as shown and lever until
disengagement occurs.
Take hold of the pad frame and pull it towards
you until the internal side clips disengage.
Pivot the pad frame outwards and lift up. Take
care not to damage the pad. Repeat these
steps for the remaining pad frames.
10
All manuals and user guides at all-guides.com
®
TBA Evaporative Cooler

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tba250Tba350Tba450Tba550

Tabla de contenido