INTRODUCTION
Congratulations on choosing Breezair air
cooling.
Your air cooler is built from the highest quality
materials and engineered to provide many
years of economical, trouble free cooling.
Please take a few minutes to read these
instructions so you have a full understanding
of how to operate your air cooler. Your
installer should demonstrate the features and
procedures set out in these instructions. The
installer should also provide you with a Model
and Serial number, which can be filled out on
the last page.
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they have been given supervision or
instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that
they do not play with the appliance.
2
All manuals and user guides at all-guides.com
EFFECTIVE COOLING
To provide efficient cooling or ventilation the
building must have sufficient exhaust openings
to outdoors in the form of doors, windows or
other vents. To assist air circulation, open
windows or doors that are furthest from the
outlet vent in each room. In every room that has
an outlet vent, provide an exhaust opening
about 2 or 2.5 times the size of the outlet vent
in the room. Where the design of the building
prevents adequate exhaust, consideration
should be given to the provision of mechanical
extraction such as an exhaust fan.
Total minimum openings for the whole building
are demonstrated by the following table:
Please note that an average size door is 1.5m.
®
TBA Evaporative Cooler
COOLER MODEL EXHAUST OPENING
TBA250
2.0m
TBA350
2.5m
TBA450
3.0m
TBA550
4.0m
2
2
2
2