Troubleshooting - Probuilder 69360 Manual De Instrucciones

Ocultar thumbs Ver también para 69360:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50

Troubleshooting

Problem
Air leaking from top of staple
gun or around trigger.
HæftepistolAir leaking from
bottom of staple gun or
between gun and cylinder
head.
Staples driven in too deep.
The staple gun is not
working properly or is not
driving in staples properly.
Staple gun skips staples.
Klammerne The staples get
stuck in the magazine.
30
Cause
The trigger valve is
damaged.
1. Loose screws.
2. O rings worn or
damaged.
1. Loose screws.
2. Supply air pressure
excessive.
1. Supply pressure too low.
2. Staple gun needs
lubrication.
3. O-rings or gaskets are
damaged or staple gun is
defective.
1. Magazine spring is
defective.
2. Front plate or magazine
defective or dirty.
3. Cylinder ring defective
orneeds lubrication.
4. Staple gun is defective.
1. The wrong staples are
being used, or have been
inserted incorrectly.
2. Magazine loose or dirty.
3. Staple gun is defective.
Solution
Have staple gun inspected
and repaired.
1. Tighten screws
2. Have staple gun
inspected and repaired.
1. Tighten the screws.
2. Reduce pressure.
1. Increase pressure.
2. Lubricate staple gun.
3. Have staple gun
inspected and repaired.
1. Replace spring.
2. Clean front plate or
magazine.
3. Lubricate staple gun.
4. Have the staple gun
repaired.
1. Use the correct staples,
or insert staples
correctly.
2. Fit magazine correctly
and check it is clean.
3. Have staple gun
inspected and repaired.

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido