Startup; Check Connections; Turning On The System; Check Output Values - Balluff BTL6-E500-M E2 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BTL6-E500-M_ _ _ _-E2/E28-KA_ _/KE_ _/LA_ _
Micropulse Transducer - Rod Style
5

Startup

5.1

Check connections

Although the connections are polar-
ity reversal protected, components
can be damaged by improper con-
nections and overvoltage. Before
you apply power, check the connec-
tions carefully.
5.2

Turning on the system

Note that the system may execute
uncontrolled movements when first
turned on or when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no hazards
could result from these situations.
6

Versions (indicated on part label)

Supply voltage
BTL6-E500-M0450-E28-KA02
Nom. length (4 digits): M = metric in mm
Interface: E = 4...20 mA
6.1

Included in shipment

Transducer with short guide incl.
O-ring and support ring.
7

Accessories (order separately)

7.1

Magnets

Magnet BTL-P-1013-4R,
BTL-P-1012-4R
➥ ➥ ➥ ➥ ➥ Fig. 3-5
Dimensions
Weight
approx. 10 g
Housing
anodized
aluminum
Operating temp.
–40 °C to +85 °C
included in shipment
Spacer
8 mm
Material
POM (Polyoxymethylene)
5.3

Check output values

After replacing or repairing a trans-
ducer, it is advisable to verify the
values for the start and end position
of the magnet in manual mode. If
values other* than those present
before the replacement or repair are
found, a correction should be made.
* Transducers are subject to modifica-
tion or manufacturing tolerances.
5.4

Check functionality

The functionality of the transducer
system and all its associated com-
ponents should be regularly
checked and recorded.
5 = DC 10...30 V
Electr. connection: KA02:
thinner rod (if applicable)
8 = ∅ 8 mm
Rod construction, pressure tube ∅ 10.2 mm
Mounting: Plug flange
6.2
Available stroke lengths
and magnets
Part No.
BTL6...-E2-
BTL6...-E28- 50 ... 1016 mm 5 mm
Special lengths on request.
Magnet BTL-P-1014-2R
Dimensions
Weight
Housing
Operating temp.
axial centric with 2 m cable
KE02:
axial eccentric with 2 m cable
LA00,3:
axial with 0.3 m long leads
Stroke length
Increment
50 ... 1500 mm 5 mm
➥ ➥ ➥ ➥ ➥ Fig. 3-5
approx. 10 g
anodized
aluminum
–40 °C to +85 °C
5.5

Fault conditions

When there is evidence that the
transducer system is not operating
properly, it should be taken out of
service and guarded against unau-
thorized use.
5.6

Noise elimination

To avoid a equipotential bonding - a
current flow - through the cable
shield, we recommend that putting
the control cabinet and the system
in which the BTL6 is located at the
same ground potential.
Magnet BTL-P-GR-PAF
➥ ➥ ➥ ➥ ➥ Fig. 3-5
Dimensions
Weight
approx. 2 g
Housing
PA
Operating temp.
–40 °C to +85 °C
english
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Btl6-e500-m e28-ka serie

Tabla de contenido