ec_1500_2000.book Seite 63 Freitag, 12. Mai 2006 4:11 16
12 Technical data
easy cool devices
Item number
Cooling capacity
(in accordance with
ISO 5151)
Heating capacity
Number of blower levels
Dimensions
(L x W x H in mm)
Installation dimension from
the top edge of the roof
Refrigerant
Weight
230 V AC operation
Input voltage
Power consumption in
cooling mode
12 V DC operation
Input voltage
Average power
consumption in
cooling mode
Priority circuit, 230 V
Recommended dynamo
output
Recommended total battery
cap.
Only for stationary and mobile air conditioning:
Output voltage
Constant output
Peak output
Efficiency
Low voltage shutdown
Dimensions (L x W x H in mm)
Weight
All manuals and user guides at all-guides.com
Stationary air conditioning
EC-1500-AC
1500 W
800 W
2
1070 x 620 x 250 1070 x 620 x 250 1070 x 620 x 250 1070 x 620 x 250
R407C
38.5 kg
230 V/50 Hz
< 4 A
–
–
–
–
–
ECW-012VS inverter for EC-1500/2000 AC/DC
Stationary and
mobile air conditioning
EC-2000-AC
EC-1500-AC/DC EC-2000-AC/DC
1800 W
1500 W
1200 W
800 W
2
2
R407C
R407C
38.5 kg
38.5 kg
230 V/50 Hz
230 V/50 Hz
< 5 A
< 4 A
–
12 V (11 V-15 V) 12 V (11 V-15 V)
–
75 A
–
Available
≥
–
90 A
≥
–
100 A
230 V
1600 W
3200 W
Up to 90 %
10.5 V
410 x 210 x 77
6 kg
Technical data
1800 W
1200 W
2
R407C
38.5 kg
230 V/50 Hz
< 5 A
90 A
Available
≥
120 A
≥
200 Ah
63