To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable
materials close to the unit while operating.
•
The unit must be installed in a location with adequate ventilation, at least 1.2m from adjacent surfaces. Be
sure that no ventilation slots are blocked.
•
Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse
size and type.
•
Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carry-
ing handles.
•
Maximum ambient temperature (Ta) is 35°C. Do not operate the fixture at temperatures higher than this.
•
In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by
yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the near-
est authorized technical assistance center. Always use the same type of spare parts.
•
Don't connect the device to a dimmer pack.
•
Make sure the power cord is never crimped or damaged.
•
Never disconnect the power cord by pulling or tugging on the cord.
•
Avoid direct eye exposure to the light source while it is on.
•
The product is for decorative purposes only and not suitable as a household room illumination.
•
The light source of this luminaire is not replaceable. When it reaches the end of its life time, the whole unit
must be discarded.
•
DISCONNECT DEVICE: Where the MAINS plug or an appliance coupler is used as the disconnect device, the
disconnect device shall remain readily operable.
INSTALLATION
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to
avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit
is secure and able to support a weight of 10 times of the unit's weight. Also always use a safety cable that can
hold 12 times the weight of the unit when installing the fixture.
The equipment must be fixed by professionals at a place where is out of the reach of people and where nobody
can pass by or under it.
FUSE REPLACEMENT
•
With a flat head screwdriver wedge the fuse holder out of its housing.
•
Remove the damaged fuse from its holder and replace with exactly the same type of fuse.
•
Insert the fuse holder back in its place and reconnect power.
•
The fuse is located inside this compartment. Remove using a flat head screwdriver.
FIXTURE LINKING
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of
channels required by all fixtures on a serial data link determines the number of fixtures that the data link can
support.
Console
Light1
Important: Fixtures on a serial/data link must be daisy chained in one single line. Maximum recommended seri-
al data link distance: 100 meters. Maximum recommended number of fixtures on a serial data link: 32 fixtures
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX CONNECTOR CONFIGURATION
Termination reduces signal errors. To avoid signal
transmission problems and interference, it is always
advisable to connect a DMX signal terminator.
CAUTION
Do not allow contact between the common and the fixture's chassis ground. Grounding the common can cause
Manual - STAR-LASER
Light2
Light3
INPUT
www.ibiza-light.com
COMMON
DMX +
DMX-
Resistance 120 ohm
1/ 4w between pin 2
(DMX-) and pin 3
(DMX+) of the last
fixture.