edges or pass across them, and no devices
may run across it nor it may suffer any other
mechanical damage. Check the flexible
in-lead cable regularly. Do not use the
vacuum cleaner if the cable is damaged.
When replacing the extension cable, the
in-lead cable, etc. the protection class, the
protection itself and the mechanical
resistance must not be lowered.
o
Always use the in-lead cable and extension
cable recommended by the manufacturer.
o
At any repair and maintenance activity
disconnect the in-lead cable from the socket.
o
Use the socket on the vacuum cleaner only
for purposes as described in the Operating
Manual.
o
Protect the plug, the socket and the
connecting components of the in-lead cables
against water.
o
Carry out only the maintenance job as
described in the Operating Manual.
o
Do not make any changes or alterations on
the vacuum cleaner.
o
Before connection to the mains, check
nominal voltage of the vacuum cleaner.
Make sure that the voltage stated on the
machine plate complies with the local supply
voltage.
o
Never vacuum with a damaged filter.
o
Do not suck combustible dust, e.g.
aluminium dust, magnesium dust.
Danger of explosion!
o
Do not suck inflammable liquids, such as
petrol, diluents etc. There is a risk of an
explosion!
o
Before the wet cleaning, remove the filtration
bag.
o
Any maintenance job calling for opening the
upper section of the vacuum cleaner may be
performed by authorized service shop only.
o
Use only the original spare parts PROTOOL.
o
Avoid any contact of the upper section of the
vacuum cleaner with water. There is a risk of
short-circuit!
Before Bringing into Operation
The vacuum cleaner MUST NOT BE connected
to the supply mains and switched ON!
CAUTION!
The accessories are delivered in the
waste vessel of the vacuum cleaner and must
be removed before bringing the device in
operation.
1. Open the closing clamps (4) and take off the
upper section of the vacuum cleaner. Take
the parts of accessories out of the vessel
(Fig. 2).
2. Insert a filtration bag in the vessel (respect
the instructions). Push the neck of the
filtration bag tight against the input flange
(Fig. 3).
3. Mount the upper section of the vacuum
cleaner back and close the closing clamps.
Carefully block the closing clamps.
4. Connect the suction hose.
5. The operating voltage shown in the machine
plate must comply with the voltage in the
mains.
6. Connect the plug in the socket (that is
installed with a protective contact in
compliance with the safety regulations).
It is recommended to connect the vacuum
cleaner through overcurrent protection with
actuating current (PRCD).
When using extension cables, the minimum
cross-section dimensions as follows must be
observed:
Cable length
Cross section
Up to 20 m
20 through 50 m
Place the parts that conduct electric current
(sockets, plugs and interconnecting elements)
so that the protection class stays unchanged.
Check the watch for volume flow
Before suction of dust with values of maximum
allowable concentration check whether all filters
are present and put on properly. While the motor
is running, cover the suction hose, and after
approx. 1 second a warning signal will show up.
Before suction of dangerous dust with
values of maximum allowable concentration,
a safety filter must be put on!
Operation
o
Make sure that the vacuum cleaner is
switched OFF.
o
Connect the suction hose. The hose
diameter and the setting-up of the hose
diameter must comply (9).
o
Connect the plug in the properly installed
socket (socket with a protective contact).
o
Make sure that the electric tools are
switched OFF.
o
Connect the electric tools in the instrument
socket (8) on the control panel.
o
Bring the switch (3) in the position "I". The
suction motor starts running.
Position AUTO
Make sure that the electric tools are switched
OFF.
Bring the switch (3) in the position AUTO. The
2
1,5 mm
2
2,5 mm
11

Publicidad

Tabla de contenido
loading