Important! The fitting must be installed, flushed and
tested after the valid norms.
Adjustment
Correction is necessary if the temperature measured at the
take off point differs from the temperature set on the scale.
To adjust temperature proceed as follows: Turn the setting
knob until water at a temperature of 38 C comes out of the
outlet. Loosen screw of setting knob. Remove setting knob
and turn to the 38 C position. Attach setting knob again
and tighten the screw (please see page 65).
Temperature limitation
The temperature is limited by the safety check to 38 C
(100 F). If a higher temperature is required, it is possible to
override the safety stop by depressing the safety button.
Safety Function
The desired maximum temperature for example max.
42 C can be pre-set thanks to the safety function.(see
page 64)
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
Maintenance
There is no special maintenance for thermostats.
The non return valves must be checked regularly according
to DIN EN 1717 in accordance with national or regional
regulations (at least once a year).
At this time, please also check the filter (13.1) situated
on the MTC-ther-moelement (13). After assembling the
MTC-thermo-element, it is necessary to check the water
temperature at the take off point as described under the
headline „adjustment". Before the adjustment, please
check, if the warm water supply is activated and the
maximum temperature of the warm water is available at
the take off point.
To guarantee the smooth running of the thermostat, it is
necessary from time to time to turn the thermostat from
total hot to total cold.
10
All manuals and user guides at all-guides.com
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80° C
65° C
ca. 26 l/min
English
Spare parts (see page 3)
1
handle for thermostat
2
handle for thermostat
3
handle for thermostat
4
handle
5
handle
6
handle
7
flange
8
flange
9
sleeve
10
sleeve
11
fixing screw
12
sub plate
13
thermostat cartridge
noise reduction
14
15
non return valve
16
shut off unit
17
extension
18
extension
extension
19
20
adapter for handle
21
adapter for handle
22
screw
23
sealing set
XXX = Colors
000 chrome plated
090 chrome plated/gold plated
400 white/chrome plated
880 satin chrome
36391XXX
38391XXX
11791XXX
96449XXX
96421XXX
95356000
96550XXX
95191000
96439XXX
96446XXX
96454000
96447000
94282000
94073000
94074000
94009000
13595000
13597XXX
15597000
96451000
96435000
96525000
95037000