Set The High Temperature Limit Stop - Hansgrohe AXOR Starck 107151 Serie Instrucciones De Instalación/Garantía

Tabla de contenido

Publicidad

English

Set the high temperature limit stop**

Remove the clip and stop ring from the cartridge stem.
Turn the water on to one of the functions.
Turn the cartridge stem until the output water is the
desired high temperature, usually 110° - 112° F**.
Replace the stop ring so that the tooth is against the
cartridge stop. Replace the clip.
It should not be possible to turn the stem further
counter-clockwise.
**Follow all applicable local plumbing codes when setting the
high temperature limit stop.
To prevent scald injury, the maximum output temperature of
the shower valve must be no higher than 10°F.
In Massachusetts, the maximum output temperature can be no
higher than 11° F.
1

Publicidad

Tabla de contenido
loading

Tabla de contenido